CCpilot VA
1.2
Technical Manual
2017-03-13
www.maximatecc.com
36
7.3.
EMC specification
The
CCpilot VA
device has been tested for Electromagnetic Compatibility according to the following
standards.
EMC Test
Test standard
Notes
Electrical Transients
ISO 7637-2:2011
EN 61000-6-1
Pulse
Level
1
-450V
2
+37V
3a/b
-/+150V
4
-12V
5
+123V
Burst (EN 61000-4-4)
DC
± 2 kV
Signal ± 1 kV
Surge (EN 61000-4-5)
DC
± 0.5 kV
Signal ± 1.0 kV
ESD immunity
ISO 10605:2008, EN 61000-4-2
Air
± 8 kV
Contact
± 6 kV
Radiated RF immunity
(1)
ISO 11452-2:2004
EN 61000-4-3
MHz
Level
Modulation
200-1000
30 V/m 80%AM, 1kHz
MHz
Field level
80-1000
10 V/m
1400-2000
3 V/m
2000-2700
1 V/m
Induces RF immunity
(1)
ISO 11452-4:2005/Cor.1:2009 (BCI)
EN 61000-4-6
MHz
Level
Modulation
20-200
60 mA
80%AM, 1kHz
MHz
Level
0.15-80
10 V
Radiated RF emission
(1)
ISO 13309:2010
EN 61000-6-4:2007
Narrow-b.
Broad-b.
MHz
dBµV/m
dBµV/m
30-75
54-44
64-54
75-400
44-55
54-65
400-1000
55
65
MHz
dBµV/m
Distance
30-230
40
10 meters
230-1000
47
10 meters
1000-3000
76
3 meters
3000-6000
80
3 meters
(1) Compliance to RF immunity and RF emission standards require use of shielded cables for Ethernet, USB and Video interfaces.
EMC tests are performed at 24 V
DC
supply voltage unless other levels are specified in test standards.
System level compliance to EMC standards may be affected by external factors like mounting, omitting
the use of shielded cables etc.