Digital input levels (5V)
Typical input amplitude
Rising threshold
Falling threshold
Hysteresis
“5V” modes (applies to both Digital and Frequency modes)
3.0 – 7.0 V
2.48 V (typ) (± 5 %)
2.41 V (typ) (± 5 %)
77 mV (typ) (± 2 %)
Digital input levels (10V)
Typical input amplitude
Rising threshold
Falling threshold
Hysteresis
“10V” modes (applies to both Digital and Frequency modes)
7.0 – 14 V
4.95 V (typ) (± 5 %)
4.79 V (typ) (± 5 %)
155 mV (typ) (± 2 %)
Digital input levels (32V)
Typical input amplitude
Rising threshold
Falling threshold
Hysteresis
“32V” modes (applies to both Digital and Frequency modes)
14 – 36 V
9.99 V (typ)
(± 5 %)
9.68 V (typ)
(± 5 %)
316 mV (typ) (± 2 %)
Frequency measurement
Frequency range
Channel 1-4
Channel 5-8
Duty-cycle range
Time base
Accuracy
Channel 1-4
Channel 5-8
Input amplitude ranges according to above.
0.1 Hz – 100 kHz
0.1 Hz – 20 kHz
40-60%
Exceeding above duty-cycle limits may cause inaccurate readings.
72 MHz
(± 100 ppm)
± 0.02 % (typ) up to 15 kHz
± 0.50 % (typ) up to 100 kHz
± 0.50 % (typ) up to 15 kHz
Input jitter (pulse time variations) will affect accuracy, especially at high frequencies. Averaging may be
used to increase accuracy.
Selectable pull-down
9.1 kΩ (± 3 %) to main supply ground.
Pull-downs available for all eight Inputs.
Selectable pull-up
9.1 kΩ (± 3 %) to main supply voltage.
Pull-ups available for Inputs 4-8 only.
Voltage (5V)
Range (min)
Accuracy
Resolution
Input Impedance
0 – 5.5 V
DC
± (0.5% + 1 mV)
1 mV
54.0 kΩ
(± 1 %)
Voltage (10V)
Range (min)
Accuracy
Resolution
Input Impedance
0 – 11.0 V
DC
± (0.5% + 2 mV)
1 mV
40.7 kΩ
(± 1 %)