9
EN
Fusing charging station
Maxem is a control system that regulates the load of the charging station. Maxem makes
sure that there is less load on the charging station when there is more load on the house.
This reduces the diversity factor. The charging station can therefore be fused to a value
higher than normal, but not higher than the threshold value of the main grid connection.
For more information on this subject in relation to the NEN1010, see the Maxem website.
Power supply
Charging station capacity Maximal fusing, charging station
3-phase 25A
3-phase 32A
3-phase 25A
3-phase 25A
3-phase 16A
3-phase 16A
3-phase 35A
3-phase 32A
3-phase 32A
1-phase 25A
1-phase 32A
1-phase 25A
1-phase 40A
1-phase 32A
1-phase 32A
Current transformers of kWh-meters
Maxem is standard supplied with current transformers with which the main grid connection
and solar production can be measured. For more accurate measurements it is also possible
to use MID certified kWh-meters. The kWh-meters Maxem works with can be ordered
separately.
There are situations when a kWh-meter is always required:
•
Measurement of a Tesla Wall Connector
•
Measurement of a heat pump