PRECAUTION
Precautions
c. Use a SSVM or VOM with 1000 ohms per-volt or higher sensitivity to measure the AC voltage
drop across the resistor (see Figure 1-1).
d. Connect the resistor to an exposed metal part having a return path to the chassis(metal cabinet,
screw heads, knobs, shafts, escutcheon, etc.) and measure the AC voltage drop across the
resistor.
e. Any reading of 5.25 Volt RMS ( this corresponds to 3.5 milliampere AC ) or more is excessive
and indicates a potential shock hazard. Correct the shock hazard before returning the monitor to
the user.
1-1-4 Product Safety Notices
Some electrical and mechanical parts have special safety-related characteristics which are often not
evident from visual inspection. The protection they give may not be obtained by replacement that
does not have the same safety characteristics as the recommended replacement part may create
shock, fire and /or other hazards. Product safety is under review continuously and new instructions
are issued whenever appropriate.
AC Voltmter
1500
0.15
Test Probe
To Exposed
Metal Parts
To Known
Earth Ground
Figure 1-1.
Leakage Current Test Circut