6–4
SPECIFICATIONS
www.maxcessintl.com
GMA-BL
MI 1-916 1 B
Inputs and outputs
Sensor input (2)
– Max Input ±20 mA
Individually programmable – 0 to 10 mA (Preferred)
digital port
– Six Digital Inputs, active high
Low level: 0 to 0.9 V
High level: 3.6 to 24 V
– Four Outputs, open collector
55 mA at 1.6 V saturation
M30 VDC applied to
output
+12 V available to port for input
reference
Supply to accessories
–
–
+12 V ±5%, 600 mA
-12 V ±5%, 80 mA
Maximum cable lengths
Power cable (18 AWG)
– 15 m (50 ft) suggested. (Longer
cables may be used if the voltage at
the GMA-BL is verified to be within
the required 18-30 VDC input
range). The suggested maximum
length is 20 m (65 ft).
Sensors
– 50 m (165 ft)
Digital input/Output port
– 50 m (165 ft)
RGPC-50/F
– 100 m (330 ft)
Operator interface
– 30 m (98 ft)