3-3
OPERATION
www.maxcessintl.com
Fife GMA-BL
MI 2-264 1 B
Optional manual configuration
1.
To manually change the System Gain. Refer to Figure 7, shown on the following page.
1)
Press the SETUP button to enter the Setup menus.
2)
Press the GAIN icon to enter the Gain menu.
3)
Use the + and - ARROW buttons, or use the slider control to adjust the Gain to
the desired level. (The display indicates the sensor signal stability to assist in the
Gain adjustment).
4)
Press the ACCEPT (√) button to save the new Gain value.
5)
Press the BACK or HOME button to return to the Operator Level screen.
12.
To manually change the Guide Point while in Automatic Mode or Manual Mode.
6)
Press the right arrow button near the bar graph to move the Guide Point toward
the right sensor.
7)
Press the left arrow button near the bar graph to move the Guide Point toward the
left sensor.
8)
Press the center round button near the bar graph to reset the Guide Point to the
default of 50%.
Figure 5.
CONTROL PANEL
AUTOSETUP SCREEN
Figure 6.
CONTROL PANEL
SUCCESSFUL AUTOSETUP COMPLETION