TROUBLESHOOTING
10 - 3
D-MAXE with OI-B/OI-N
www.maxcessintl.com
MI 2-296 1 D
Feh
lersu
che
.fm
D-MAX operator
interface
While the device is being turned on, the LEDs on the D-MAXE
Controller are lit red briefly. This makes it possible to check
their functionality. The LEDs indicate errors and/or show
information about normal operation of the D-MAXE Controller.
LED
Status
Indicates
Remedy
Error messages
EN
Off
No Ethernet connection
Check plug and cable
PWR
Off
No power supply
Are the power supplies correctly
connected to the X6?
Electrical connection, page 3-6
Is the fuse blown?
Green
flashing
Power supply voltage too low,
internal voltage outside
tolerance or internal
temperature too high
Check voltages and/or temperature
See
Menu 1y.9.1.7 Power, page 7-57
Information
EN
Green
Ethernet connection detected
Green
flashing
Connection detected and
device is PTP Master
PWR
Green
Power supply and temperature
are OK