45
RIOTRONIC X+
User Manual
6.11.
Troubleshooting
Problem
Possible cause
Action
Logger won’t start
Very low batter level
Connect battery charger
Error “OPEN LINE”
Bus line or detonator is
disconnected
Connect Bus line or detonator and try
again
Error “SHORT LINE”
Bus-line is shorted
Remove the short circuit and try
again
Error “PIN ERROR”
Entered PIN is incorrect
Try to enter user or admin PIN again
NFC transfer won’t start NFC antennas are not aligned
NFC sending and receiving antennas
must be precisely aligned
6.12.
Technical specification
Parameter
Value
Dimensions
125 x 219 x 37 mm
Operation temperature
-15°C, +55°C
Charging temperature
0°C, +40°C
Storage temperature
-20°C, ÷ +50°C
Charging supply voltage
10÷12 V DC
Battery voltage
7,2V
Battery capacity
5,2Ah
Battery type
Li-Ion
Display type
LCD
Display size
3,5”
Display resolution
320x480
Maximal Bus-line length
1000 m
Number of supported detonators
up to 500
Bus-line voltage
10,5 V