83
5.2 Troubleshooting Checklist
This section helps users to detect possible causes to certain
problems occurred, and provide feasible solutions to handle
certain operation failures.
A.
When the aircraft indicates failure during self-check
(with 4
LED lights flashing slowly in red and the buzzers beep all the time)
9
Check if the IMU is properly calibrated through the PC Aid or
X-Star Mobile App
9
Check if the remote controller parameters are properly
calibrated
B.
When the aircraft motors fail to start up
9
Check if the remote controller and the aircraft are properly
paired
9
Check if the remote controller parameters are properly
calibrated
C.
When take-off fails after motors are initiated
9
Check if the Smart Control Switch is in the Normal position
(flipped up)
9
Make sure the Flight Mode Switch is not in the GPS position
when the GPS satellite signals are less than 6
9
Check if the battery level is high enough
9
Check if the aircraft is in no-fly zone
9
Check if the aircraft is placed on a flat ground
D.
When the aircraft’s flight time reduces
9
Make sure the battery is in a warm environment before use