background image

 

- 3 -

 

 

 

CAUTION

 

 

The  data  stored  in  the  internal memory  or  the memory  card  cannot  be  stored  perma-
nently.    We will not be responsible for damages and lost profits caused by loss of data 
attributed to battery consumption, trouble, repair, and so on. 

 

Never disassemble or modify this instrument.    It  could  cause a  fire, electric shock, or 
other problems. 

 

  Do  not  insert  foreign  substances  such  as  fingers,  pens,  wire,  or  paper  into  this in-

strument.    It could damage the instrument or cause a fire. 

  Use correct supply voltage.    Other voltage level could damage the instrument. 

  Do  not  splash  water  or  chemicals  on  the  instrument.    If  water  gets  inside  the  in-

strument, disconnect the power  plug immediately from the plug  socket  and contact 
your  dealer/distributor for a repair.    It could  damage  the  instrument  or  cause  a fire 
or electric shock. 

 

Do not put paper or cloth on the instrument.    It could cause a fire. 

  Do not place any heavy material on power cord.    It could cause damage or a fire. 

 

  Never  touch  the  printer  head.    It  is  very  hot  just  after  printing  and  you  could  get 

burned.    Also, dirt on your hand could cause trouble to the printer head. 

 

  When the instrument is not going to be operated for a long period of time, be sure to 

disconnect the power cord from the power socket for your safety. 

  When disconnecting the power cord, be sure to hold the power plug.    Do not pull on 

power cord, or the cord could be broken and cause a fire or electric shock.

 

 

 

 

 

 

ACCESSORIES 

This  instrument  comes  with  the  following  accessories.    Confirm  that  they  are  included  before 

using the machine. 

1.  Instruction manual 

2.  Screws for wall mounting 

 

 

 

: 1 booklet   

 

 

 

  : 2-pcs. 

 

 

- 4 -

 

   

  Do not drop or hit the instrument. 

 

  Install this instrument away from the following places:   

1. Any place that is not level or that is subject to vibration. 

 

2. Any place that has dust or high humidity.    Keep beverages and 

liquid containers away from this instrument. 

 

3.  Any  place  that  the  temperature  goes  below  0

  /32

  or  over 

40

/104

 

4.  Any  place  that  catches  direct  sunlight  or  is  located  close  to  a 

heat source. 

 

  Do not insert cards or paper other than the specified time cards for 

this instrument.    Do not use time cards that are bent or torn. 

 

 

  Be  sure  to  use  a  dry cloth for  cleaning.    Do not  use solvents (al-

cohol, benzene, thinner, etc.) or a damp cloth. 

 

  Do  not  re-ink  cartridge.  Replace  with  ink  ribbon  cassette 

ER-IR103. 

 

  Do not hang this instrument  on a  wall  using  anything  other  than the included plate for wall 

mounting.

 

The socket-outlet shall be installed near the equipment and shall be easily accessible. 

  A 30-minute break is required after continuous printing for 15 minutes.

 

 

Summary of Contents for ER-1600

Page 1: ......

Page 2: ...data Describes operations that may cause damage to the instrument and require a re pair or operations that require resetting the machine etc to restore the condition of the instrument Describes the p...

Page 3: ...me be sure to disconnect the power cord from the power socket for your safety When disconnecting the power cord be sure to hold the power plug Do not pull on power cord or the cord could be broken and...

Page 4: ...o reset the time PARTS DESCRIPTIONS HOW TO OPEN AND CLOSE FRONT COVER Pull as illustrated above Remove the front cover Push as illustrated above Front cover Time card insertion slot Display External k...

Page 5: ...ing the time in the 4th column 8 SETTING OR CHANGING DATA Operation 1 Press CANCEL key for 3 sec or more The symbol appears on the display 2 After setting or changing data press the CANCEL key again T...

Page 6: ...ode Pay Closing Date is shown on the display Monthly Press the or key to select the Pay Closing Date When the display shows the desired closing date press the SET key from to Weekly Press the or key t...

Page 7: ...yle that has been selected Press the or key to select the desired number from the following table Number Style of Daily Total Time 1 Regular work time 2 Overtime work 1 If 2 Overtime work is set but t...

Page 8: ...YEAR MONTH DATE HOUR AND MINUTE MODE 2 Procedure 1 Press the CANCEL key for 3sec or more The symbol appears on the display to in dicate the setting mode is on If password has been set up enter the pas...

Page 9: ...e End Ending date of Daylight Saving Time 08 16 Procedure 1 Setting IN OUT and starting time of Overtime Work Example Line Shift Time Day change time 4 00 Starting time of work 9 00 Starting time of l...

Page 10: ...k Press the SET key to register the Week Move the cursor to the position of SUN for the day of the week by pressing the or key Press the SET key to register the day of the week 1 During the period of...

Page 11: ...lustrated Then turn the knob again to remove the slack in the ribbon 5 Close the front cover and connect the power cord 20 WALL MOUNTING AND LAID DOWN POSITION INSTALLA TION CAUTION If mounting on a w...

Page 12: ...cting the power cord 22 CAUTION CODE Caution Code Problem Solution When you try to revise Machine Mode Pay Closing Date Date LST 60 100 scale or Daily Total Time all time data is deleted If you press...

Page 13: ...ute AM PM Day of week Printed information Date Hour minute Up to 4 columns Daily Total Time Symbol of Guarantee in case of power failure Memory backup supported by an internal battery and a clock func...

Page 14: ...nual is subject to change without notice due to functional enhancement 6 6 NIHONBASHI HAKOZAKI CHO CHUO KU TOKYO JAPAN POST CODE 103 8502 TELEPHONE 81 3 3669 8131 FAX 81 3 3669 7104 URL http wis max l...