3.05
TI013G0008
Air Tank (unit in version BLADE - TM)
The tank comes with INSTRUCTIONS,
USE, AND MAINTENANCE GUIDE that
should be kept and referred to before
any use of the tank. It is also comes with
a CONFORMITY DECLARATION that
clearly states the main technical data and
the operating limits.
The tank contains compressed air; always
consider the potential danger deriving from
improper use.
The tank may contain condensation with
oil residuals. Always consider the related
ruling regulations for disposal.
The tank should be used as an air
compressed accumulator only and it should
be operated within the speci
fi
ed limits
shown on the technical data plate.
No modi
fi
cations should ever be made
to either this tank or its installation when
setting up the machine.
The maximum operating pressure and
temperature of this tank are shown on the
attached plate.
The setting of the safety valve guarantees
the maximum tolerated operating pressure.
The tank has been designed and made so
that to guarantee its use for a long period
of time.
As it is shown in the guide supplied, extra
thickness has been foreseen against any
possible corrosion.
Inspections during its running might be
required by the different national laws.
In the on-tank version, the machine comes
complete with a condensate separator and
a solenoid valve with timed and adjustable
exhaust (see condensate exhaust section,
tank version “BLADE-TM”)
CONTROL DEVICE - MANAGEMENT
AND CONTROL OF A MICROPROCES-
SOR “MAESTRO XB”
MAESTRO XB is a programmable control
unit which adapts compressor operation
to the speci
fi
c requirements of the air
line it is connected to. It features various
programming levels and performs operating
and fault controls and analysis.
Advanced programming and analysis levels
are protected by digital codes to prevent
unintentional access.
MAESTRO XB also contains a memory
which saves settings and operating data
even if the compressor is disconnected
from the power supply or switches off due
to a power cut.
Hardware Characteristics
- Microprocessor-based technology
- Ergonomic control panel with rapid
access keys to main menus
- access keys, start/stop and reset keys
- led backlit LCD display, 2 lines, 20
characters
- 24 Vac 50/60Hz Power Supply
- 24 Vdc Digital Inputs
- Digital output with clean contacts up to
230 Vac and until 24Vdc
- Pressure analog signals (4-20mA)
- Temperature analog signals (NPT)
Interfaces:
RS485 to comunicate with supervisor
PC and network
Description of machine