8-9.Failure Setup. In Setting
【
Menu
:
1-5
】
This item sets the signal level used for recognizing the input signal as error signal.
The upper and lower limits should be set.
・
For the upper limit, if a signal higher than the setting value is input, the signal is recognized as error signal.
・
For the lower limit, if a signal lower than the setting value is input, the signal is recognized as error signal.
* When the input signal is 0 mA, it is recognized as "No sensor".
Setting range: Upper limit = 20 - 24 mA (default value: 20.5 mA)
Lower limit = 3 - 4 mA (default value: 3.8 mA)
Menu 0
▶
1. Basic setup
2. Test
3. Reset
4. Language
5. Device info
O K ×1
O K ×1
Basic setup 1
▶
1. Display
2. Relay output
3. Analog output
(S. failure mode)
4. Damping
5. Failure setup. In
(Measuring screen)
+ ×4
ESC ×3
O K ×1
( Setting is saved )
( Use ESC button to return
to the measuring screen. )
Failure setup. In 1-5
Upper ( 20.0 – 24 mA )
▶
2
0
.5 mA
Lower ( 3.0 – 4.0 mA )
3.8 mA
Failure setup. In 1-5
Upper ( 20.0 – 24 mA )
▶
22.
0
mA
Lower ( 3.0 – 4.0 mA )
3.8 mA
(
A blinking
indicates the
item to be set. )
Use
▶
and + buttons to
change the value to 22.0.
O K ×1
Failure setup. In 1-5
Upper ( 20.0 – 24 mA )
▶
22.0 mA
Lower ( 3.0 – 4.0 mA )
3.8 mA
5 0.0
Failure setup. In 1-5
Upper ( 20.0 – 24 mA )
▶
20.5 mA
Lower ( 3.0 – 4.0 mA )
3.8 mA
%
(Measuring screen)
O K ×1
*For example, “Upper limit”
is
set to 22mA.
5 0.0
%
Basic setup 1
1. Display
2. Relay output
3. Analog output
(S. failure mode)
4. Damping
▶
5. Failure setup. In