Chapter 9 Troubleshooting
- 55 -
[WO-4841
;
JL4-V
・
VC-55]
Blower does not rotate.
Location to be checked
Action
Precaution
Check that foreign matter is not
caught in the blower fan.
Remove the fan cover to
remove foreign matter.
Turn “OFF” the primary power supply and
power circuit breaker before carrying out
work.
Check that the Jet Clone limit
switch operates normally.
*
Only when the Jet Clone
type limit type collection
hopper is used.
Replace the limit switch.
For purchase of the limit switch and type,
contact Matsui SDI.
Check that the Jet Clone gate
can is properly adjusted.
*
Only when the Jet Clone
type limit type collection
hopper is used.
Refer to Chapter 8 Inspection
and Maintenance to adjust the
gate cam.
A condition when the limit switch is “ON.”
材 料
Check that the suction hopper
proximity switch detects
normally.
*
Only when the suction
hopper type E2K control is
used.
Refer to Chapter 8 Inspection
and Maintenance to adjust the
sensitivity of the proximity
switch.
If the proximity switch does not
operate normally even after the
sensitivity adjustment, replace
it.
For purchase of the proximity switch and
type, contact Matsui SDI.
Check that the suction hopper
level switch detects normally.
*
Only when the suction
hopper type level switch
control or SD control
collection hopper is used.
Refer to Chapter 8 Inspection
and Maintenance to adjust the
sensitivity of the level switch.
If the level switch does not
operate normally even after the
sensitivity adjustment, replace
it.
For purchase of the level switch and
type, contact Matsui SDI.