Chapter 3 Installation
- 16 -
[WO-4841;JL4-V
・
VC-3
~
6-16]
Step
Task
Description
6
Supplying compressed
air to collection hopper
air kit
*
Only when the
collection hopper is Jet
Clone pneumatic
cylinder control type or
suction hopper type has
ASD control.
(not common)
Connect an air hose for a compressed air source to the air supply
port valve of the automatic slide gate air kit from your existing source.
↓
Fully open the valve of the air kit to supply dry compressed air of 0.5
MPa or higher from the compressed air source.
↓
Set the filter regulator outlet pressure of the air kit within a range of
0.4 to 0.5 MPa.
①
Pull up the filter regulator adjustment knob to unlock it.
②
Adjust the indication of the pressure gauge to 0.4 to 0.5 MPa
by turning the adjustment knob clockwise or counterclockwise.
Turning the knob clockwise causes the indicated value to rise,
and vice versa.
③
After setting the pressure, push down the adjustment knob to
lock it.
NOTE
○
Secure pressure of 0.5 MPa or higher for dry compressed air from
the compressed air source.
Properly process with an air dryer or air filter to use clean dry
compressed air. Sufficiently drain to prevent freezing of drain
water especially in cold climates.
Adjustment knob
Pressure gauge
Bowl
Drain valve
AutoSlide gate