Chapter 3 Installation
- 18 -
[WO-4841;JL4-V
・
VC-3
~
6-18]
Step
Task Description
3
Checking forward and
reverse phase
↓
If no air is blowing out from the exhaust port, it means that the blower
rotates in the reverse direction (reverse phase). In this case, turn OFF
the primary power and reverse the R phase and T phase of the three
wires of the power cord.
↓
Again, turn ON the primary power and check that air is blowing out
from the exhaust port.
Exhaust port