36 Chapter 4: Matrox RadientPro CL hardware reference
Camera control and auxiliary signals
The following tables summarize the auxiliary functionality that the PSGs on
Matrox RadientPro CL support, and the corresponding signals that the PSGs can
receive/generate. The table also documents the MIL constants to use.
LVDS cam. ctrl
LVDS cam. ctrl
Camera Link
Connector
0
Camera Link
Connector
1
M_CC_IO
n
n
1
2
3
4
1
2
3
4
for M_DEV
m
*
*. MIL constant, where
n
and
m
correspond to the number in the row. M_DEV
m
is the required device number
of the digitizer (
MdigAlloc()
) that you must use to access this signal.
m
0
0
0
0
1
1
1
1
Functionality
Ac
qu
isitio
n p
ath
CC
1
CC
2
CC
3
CC
4
CC
1
CC
2
CC
3
CC
4
Timer
(M_TIMER
n
*
)
0
1/2
1/2
1/2
1/2
1
1/2
1/2
1/2
1/2
User output
(bit of Camera Link static-user-output register
M_USER_BIT_CC_IO
n
*
)
0
0/1
0/1
0/1
0/1
1
0/1
0/1
0/1
0/1
VSYNC output
0
1
1
1
1
1
1
1
1
1
HSYNC output
0
1
1
1
1
1
1
1
1
1
Clock output
0
1
1
1
1
1
1
1
1
1