Natural Gas to LPG Conversion
This hob can be converted from natural
gas to propane operation at a nominal
inlet pressure of 37mbar, or butane
operation at a nominal inlet pressure of
28/30mbar. This conversion must only
be carried out by a competent person
(i.e. a Gas Safe registered fitter).
Instructions to fit replacement
injectors:
1. Disconnect the appliance from the
gas and electrical supplies.
2. Remove burner components and pan supports.
3. Remove the injectors and replace with the corresponding injector
as shown in the table on page 15.
Setting up minimum flow rates:
1. Remove the control knobs.
2. Turn on the LP gas supply, light the burners and turn the controls to
the minimum position, as indicated by the small flame.
3. Insert a 2.5mm screwdriver into the hole at the top of the tap and
turn the adjustment screw fully clockwise as shown in figure 8.
4. Turn the controls to maximum position then quickly to the minimum
position - make sure the flame does not extinguish.
5. Replace the knobs.
Required:
• 7mm AF nut spinner
• Replacement injectors
• LPG identity plate
Fig. 8