28
8.2 Error codES on tHE conSolE
codE
claSS
dEScription
SolUtion
0x02AB
C
Machine type error.
Set the correct machine type in
Engineering Mode.
0x02B3
C
Resistance type error.
Set the correct machine type in
Engineering Mode.
0x0201
A
Low voltage on the battery
(voltage under 11.2V).
Charge by running or by plugging
in the AC adapter.
0x0247
B
LCB failed (memory write error /
feedback ADC error).
Replace the LCB.
0x0248
B
Battery failure or disconnection
(Voltage under 8V or over 15V).
Check the wire connections at
the battery. Replace the battery.
0x0441
B
When the UCB implements
a command, the LCB is not
receiving this command.
Check the machine type in
Engineering Mode. Check the
connections at the UCB and LCB.
0x04A0
C
Digital Communication Failure.
LCB has no return message for
the UCB for 3 seconds.
Check the console cable
connections at the UCB and
LCB. Replace the UCB or LCB
as needed.
0x04B0
C
UCB No Response.
Check the console cable
connections at the UCB and
LCB. Replace the UCB or LCB
as needed.
claSS c ErrorS will diSplay on tHE conSolE.
claSS a or b ErrorS will only diSplay in SErVicE ModE 5.