19.8
Working with several cameras simultaneously
177
Figure 5: Connection with opto-isolated digital inputs and outputs
Symbol
Comment
Input voltage
Min
Typ
Max
Unit
U
ext.
External power
3.
←
-
3
30
V
R
out
Resistor digital output
2
kOhm
R
in
Resistor digital input
3.3 V .. 5 V
0
kOhm
12 V
0.68
kOhm
24 V
2
kOhm
You can add further slaves.
19.8.1.1.2
Connection using -UTW versions (TTL inputs and outputs)
The connection of the mvBlueFOX cameras should be like this:
Figure 6: Connection with TTL digital inputs and outputs
For this case we offer a synchronization cable called
"KS-MLC-IO-TTL 00.5"
.
MATRIX VISION GmbH
Summary of Contents for mvBlueFOX
Page 1: ...mvBlueFOX Technical Manual...
Page 22: ...5 2 European Union Declaration of Conformity statement 15 MATRIX VISION GmbH...
Page 23: ...16 CONTENTS MATRIX VISION GmbH...
Page 24: ...5 3 Legal notice 17 5 3 Legal notice 5 3 1 For customers in the U S A MATRIX VISION GmbH...
Page 53: ...46 CONTENTS Figure 3 D Sub 9 pin male digital I O MATRIX VISION GmbH...
Page 117: ...110 CONTENTS MATRIX VISION GmbH...
Page 201: ...194 CONTENTS 20 1 5 2 Color version MATRIX VISION GmbH...
Page 202: ...20 1 mvBlueFOX Model 220 0 3 Mpix 640 x 480 195 20 1 5 3 Gray scale version MATRIX VISION GmbH...
Page 203: ...196 CONTENTS MATRIX VISION GmbH...
Page 211: ...204 CONTENTS MATRIX VISION GmbH...
Page 217: ...210 CONTENTS 20 3 5 2 Color version MATRIX VISION GmbH...
Page 219: ...212 CONTENTS MATRIX VISION GmbH...
Page 220: ...20 3 mvBlueFOX Model 221 0 8 Mpix 1024 x 768 213 MATRIX VISION GmbH...
Page 225: ...218 CONTENTS 20 4 5 2 Color version MATRIX VISION GmbH...
Page 227: ...220 CONTENTS MATRIX VISION GmbH...
Page 235: ...228 CONTENTS MATRIX VISION GmbH...