MSC-XD164S Product Manual
The SetS command is used for setting system parameter Stored values only. Values set with this command will
not take effect until the system is restarted.
NOTE:
Some parameters may not be assignable in Stored memory, for example if it does not make sense to
recall a value on start up. See
for more details.
Command
Description
SetS
List all parameter identifiers which can be set in Stored memory, one per line.
SetS Parameter Value
Set a parameter’s Stored value.
3.10.42 SrcNames Command
Routers and MSC-GCP2U32 only
Query or assign source names. This command has 4 variations, described by the following table. Source names
are stored and recalled on power up.
Command
Description
SrcNames
Query all source names.
SrcNames SRC
Query source names for all levels of a given source.
SrcNames SRC, LEVEL
Query the name of a specific source and level.
SrcNames SRC, LEVEL, LABEL
Assign a label to a source.
When querying names, labels are surrounded by double quotes and each level is separated by commas ',' (multi-
level systems only) and each source is separated by newlines. Secondary levels use empty strings to indicate
that the label of the first level should be used.
Examples
>SrcNames
“Src1”,”AudSrc1”
“Src2”,””
“Src3”,””
“Src4”,””
>SrcNames 1
“Src1”,”AudSrc1”
>SrcNames 1,2
“AudSrc1”
>SrcNames 1,2,””
>
The first 3 example commands are query commands. The last assigns an empty string to the second level of the
first source (thereby indicating that the first level label should be used).
3.10.43 SysName Command
NOTE:
Superseded by the
sys.name
Query or assign system name. The system name is provided for convenience when managing multiple Matrix
Page 47 of 60
© 2013-2016 Matrix Switch Corporation