MSC-XD164S Product Manual
3.10.37 S Command
Routers and MSC-GCP2U32 only
Query the current matrix routing state. Source values for all levels of every destination are shown. This
command without an argument is equivalent to the
with no arguments. If an argument value of '1'
is supplied, then the matrix state is displayed with labels. The state of each destination is displayed, one per
line, in the format:
“DestNLvl1”:”SrcLvl1”,”DestNLvl2”:”SrcLvl2”,...
Example
>S1
“Dest1”:”Src4”,”Dest1”:”Src4”
“Dest2”:”Src3”,”Dest2”:”Src3”
“Dest3”:”Src2”,”Dest3”:”Src2”
“Dest4”:”Src1”,”Dest4”:”Src4”
The example above is output from a two level (Video and Audio for example) 4x4 matrix with sources routed in
reverse order, except destination 4, which has a 2nd level break away which is routed from source 4.
3.10.38 SerBaud Command
NOTE:
Superseded by the
ctl.serial.baud
and
ctl.serial2.baud
Query or assign the RS-232 serial port baud rate. The default value is 115200. This value is stored and recalled
on power up.
Command
Description
SerBaud
Query the current serial port baud rate.
SerBaud BAUD
Set the serial port baud rate.
Examples
>SerBaud
115200
>SerBaud 9600
>
The first example command queries the serial baud rate value which is the default of 115200 and the second
command sets it to 9600 baud.
3.10.39 Set Command
Protocol version 3.0
The Set command is used for assigning values to system parameters. See the
for a list
of currently defined parameters. This command supersedes many individual configuration commands.
NOTE:
This command may set Active and/or Stored parameter values. Behavior depends on the parameter and
. Values in Stored memory are loaded at system startup. See
for more details.
Page 45 of 60