8.10 troUblEsHooting - Error 0149
cHAPtEr 8: troUblEsHooting
figUrE A
Error codE 0149
1) syMPtoM:
0149 – The resistance current is over 3.7A for 1 second.
2) solUtion:
1) Check if the resistance is short circuited by measuring amperage through the generator cable (Figure A).
- If the resistance value is under 10 ohms, replace the generator.
- If the resistance value is over 10 ohms, replace the LCB.