x 3
x 3
x 3
b
a
2.5mm
Ø6
SILICON
x 3
x 3
STAGE 1
TOP VIEW
FIXED PANEL
WALL MOUNT
THRESHOLD
This stage is describing the fitting of the Fixed panel wall mounts
Before fitting the enclosure please check that your product will fit the finished aperture size.(See dimensions)
a.
Remove and set aside the threshold cover from the horizontal threshold. Place the horizontal threshold into position on tray. (If fitting
close to the front edge of the tray take into account that the front face of the fixed panel wall mount sits 2.5mm in front of the threshold). The
Pivot point in the threshold determines the handing of the door, for a door pivoting from the LH side, pivot point should be on the LH side, and
right for RH pivoting. Position the closure fixed panel wall mount on to the wall over threshold (wall mount has a top and bottom, Wall mount
cut-out with socket set screw is the top of the wall mount). Ensure the threshold adjuster fits up into the back of the wall mount extrusion in the
recess as shown. Adjust position of threshold adjuster as required, to adjust loosen screw 1 full turn, re-tighten after adjustment, do not over
tighten. Plumb the wall mount for upright and mark the fixing holes in the centre of the slots.
b.
Drill 3 x fixing holes in the wall and insert wall plugs. Clean area and apply silicon sealant to the area behind the wall mount between the
tray and tiles and 100mm up the wall, central to the width of the wall mount. Fit the wall mount using the No.8 x 32mm Pan Head Screws.
c.
Repeat as above for fixed panel wall mount on the pivot block side.
THRESHOLD
ADJUSTER
WALL
MOUNT
THRESHOLD
TOP
SEE DIMENSIONS
PIVOT POINT
(IMAGE SHOWS A
LH PIVOTING DOOR.
ROTATE THRESHOLD
BY 180° FOR RH
PIVOTING DOOR)