REV 0/00
Stop Trol?
Alm Trol
End Irrig
If during the working cycle the rewinding speed equal to zero for more than 3
minutes, this message will be displayed. This is the time needed by the console to
establish that the trolley is stopped.Therefore the speed adjustment motor is
controlled automatically to reach the programmed speed. Find out why the trolley
is stopped.
This is the case when the "Stop Carr?" condition persists for more than 9 minutes.
When the Alm Carr message is displayed the irrigation cycle is interrupted by
the normal end-of-work procedure. (See par. 10.1 page 15).
Possible causes:
A)
Lack of pressure (and pressure switch not connected)
B)
Carriage locked
C)
Turbine locked
D)
Speed sensor out of order
E)
Feeler roller jammed or skidding. (Only if equipped with one)
This message is displayed at the end of the irrigation cycle until the console is
switched off and indicates the irrigation has been ended regularly.