background image

INSTRUCTIONS FOR:

PLATFORM SCAFFOLD TOWER

EXTENSION PACK 3 

Model No.

 

SSCL3

Thank  you  for  purchasing  a  Sealey  product.  Manufactured  to  a  high  standard  this  product  will,  if  used  according  to  these  instructions 

and properly maintained, give you years of trouble free performance.

IMPORTANT:

 

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 

PERSONAL  INJURY  AND  WILL  INVALIDATE  THE  WARRANTY.  PLEASE  KEEP  INSTRUCTIONS  SAFE  FOR  FUTURE  USE.

1.  SAFETY INSTRUCTIONS

  

WARNING! Take care when using and moving scaffolding,    

 

extended ladders and other such equipment in the vicinity    

 

of power cables - risk of potentially fatal electric shock.

  

WARNING!

 Ensure Health and Safety, local authority, and 

 

general workshop practice regulations are adhered to when  

 

 

using this equipment.

3

 

Familiarise yourself with the application and limitations of the 

 

scaffold, as well as the potential hazards.

3

 

Maintain the equipment in good condition. 

7

 

DO NOT

 use the equipment if any parts are damaged or missing  

 

as this may cause failure and/or personal injury. 

3

 

Replace or repair damaged parts. Use genuine parts only. 

 

Non-authorised parts may be dangerous and will invalidate the 

 

warranty.

3

 

Keep the work area clean, uncluttered and ensure there is 

 

adequate lighting.

 

WARNING!

 Use scaffold on level and solid ground and ensure    

 

the brakes are applied and/or that the scaffold is anchored and   

 

held firmly in place by some means.

 

WARNING!

 DO NOT erect or use the scaffolding on sloping or    

 

unstable ground. 

 

WARNING!

 Never over-reach when on the scaffolding.

3

 

Keep children and unauthorised persons away from the working  

 

area.

7

 

DO NOT

 use the scaffolding for any purpose other than that for   

 

which it is designed.

7

 

DO NOT

 allow children to climb the scaffolding.

7

 

DO NOT

 use the equipment when you are tired, under the 

 

influence of alcohol, drugs or intoxicating medication.

3

 

When not in use store in a safe, dry, childproof area.

7

 

DO NOT

 use the equipment without side guardrails, knee rails    

 

and toeboards fitted. Use all the components supplied.

3

 

When used outside, mobile scaffold towers should, wherever    

 

possible, be secured to a building or other reliable structure. 

3

 

It is good practice to tie in all scaffold towers of any height, 

 

especially when left unattended or in exposed windy conditions.  

 

Use only the recommended wall anchors.

3

 

Beware of strong wind conditions. Do not erect or use a 

 

freestanding tower if the wind is likely to exceed 7.7 m/sec  

 

 

(17mph or Beaufort force 4). 

3

 

Take care when using mobile scaffold towers in hangers or  

 

 

uncovered buildings as wind force may be increased due to 

 

funnelling effects.

7

 

DO NOT

 climb a tower from the outside. Never climb on the 

 

horizontal or diagonal braces. You should only climb the tower on  

 

the inside using the ladder end frames.

7

 

DO NOT

 lean ladders against the tower. Never use ladders or    

 

boxes to gain additional height.

3

 

Ensure that all personnel, tools and materials are removed from  

 

the tower prior to moving it. Only move the scaffold tower 

 

manually on a firm level surface, which is free of any obstacles.   

 

Only move it longitudinally or diagonally. Do not exceed normal   

 

walking speed. Raise the stabilisers 12 mm (½”) from the ground.    

 

After moving re-lock the castors, check that the tower is level    

 

and ensure that the stabilisers are secure and have a firm footing.

7

 

DO NOT

 exceed the safe working load of the platform. The 

 

maximum capacity of the working platform for an evenly 

 

distributed load is 1.5 kN/m² (according to HD1004 – scaffold    

 

tower Class 2) 

7

 

DO NOT

 jump on to or off the platforms.

7

 

DO NOT 

use any lifting equipment on the mobile scaffold tower.

2.  INTRODUCTION

Extension Kit for the SSCL1 (EN1004 Approved) Scaffold Tower 

System designed to meet the UK PASMA T3 standards. Increases the 

platform height to 3.5mtr and the working height to 5.5mtr. 

Manufactured from robust aluminium with anodized finish for durable 

corrosion resistance. Supplied with stability legs to stabilise unit and an 

extra trap door platform.

3.  SPECIFICATION

  

Model No: ......................................................................................SSCL3 

Width: ......................................................................................... 1780mm 

Width with support legs: ............................................................. 3810mm

Depth ............................................................................................ 860mm 

Maximum Working Height: ............................................................5.5mtr* 

Maximum Platform Height: ............................................................3.5mtr*

Maximum capacity ...........................................................................200kg 

Weight: ..............................................................................................35kg

*Only when used with SSCL1

7

 

DO NOT

 bridge between the mobile scaffold tower and buildings. 

3

 

Stabilisers and ballast weights shall always be fitted where 

 

specified. Ballast is used at the base to stabilise towers from    

 

overturning. Ballast must be of solid material (i.e. NOT water or   

 

loose sand) and should be positioned so as not to overload 

 

individual legs. Ballast should be secured from accidental removal.

3

 

Keep equipment clean and inspect before and after use for 

 

damage. Use serviceable equipment only. All working parts e.g.   

 

castors, adjustable legs; stabiliser clamps should be lubricated    

 

lightly with oil. Repairs should only be carried out by the supplier  

 

or other competent person approved by the supplier.

4.  CONTENTS

 Reference 

Description 

Quantity

 

B

 

Diagonal Brace 

2

 

C

 

Horizontal brace 

4

 

H

 

Trapdoor Platform 

 

F

 

6 Rung End Frame 

 

G

 

Stabiliser Leg 

Original Language Version

SSCL3   Issue No.1 - 10/06/10