17
IEC/EN61010-2-032 Ed. 3.0 & IEC/EN61010-031 Ed. 1.1 to CAT III
600V and CAT IV 300V AC & DC
Transient Protection:
6.0kV (1.2/50
s surge)
Overload Protections:
Current & Hz functions via jaws: 600ADC/AAC rms at <400Hz
Voltage & 3-Phase Rotation functions via terminals: 660VDC /
920VAC rms
Other functions via terminals: 600VDC/VAC rms
E.M.C.:
Meets EN61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-
3, EN61000-4-2, EN61000-4-3, EN61000-4-4, , EN61000-4-5,
EN61000-4-6, EN61000-4-8, EN61000-4-11):
DCA and DC+ACA Functions, in an RF field of 1V/m:
Total Accuracy = Specified Accuracy + 20 digits at around
405MHz
DC
A and Ohm Functions, in an RF field of 1V/m:
Total Accuracy = Specified Ac 25 digits
Other Functions, in an RF field of 3V/m:
Total Accuracy = Specified Ac 20 digits
Power Supply:
1.5V AAA Size battery X 2
Power Consumption:
Typical 13mA
Low Battery:
Below approx. 2.85V for Capacitance & Hz
Below approx. 2.5V for other functions
APO Timing:
Idle for 32 minutes
APO Consumption:
5
A typical
Dimension (LxWxH):
223 x 76 x 37mm
Weight:
234gm
Jaw opening & Conductor diameter :
35mm max
Accessories:
Test lead set, User's manual, Soft carrying pouch,
Bkp60 banana plug K-type thermocouple Alligator Clip set
Optional purchase accessories:
BKB32 banana plug to type-K socket
plug adaptor
Special Features:
AmpTip
TM
low-current range; MAX/MIN/AVG
Recording mode; Display Hold; EF-Detection (NCV); Backlighted LCD;
80ms Peak-RMS mode for inrush current; Relative-Zero; 3-Phase