background image

014-03 - Gas fry-top

5

Model

ADH30007

ADH30008

ADH30009

ADH30010

ADH30011

ADH30012

AEH30007

AEH30008

AEH30009

AEH30010

AEH30011

AEH30012

Description

Gas fry top - smooth plate

Gas fry top - smooth chromium top plate

Gas fry top - grooved plate

Gas fry top - smooth plate - 2 cooking zones

Gas fry top - smooth chromium top plate - 2 cooking zones

Gas fry top - grooved plate - 2 cooking zones

Gas fry top - 1/2 1/2 grooved plate - 2 cooking zones

Gas fry top version - 1/3 g 2/3 smooth plate - 2 cooking zones

Gas fry top - smooth plate

Gas fry top - smooth chromium top plate

Gas fry top - grooved plate

Gas fry top - smooth plate - 2 cooking zones

Gas fry top - smooth chromium top plate - 2 cooking zones

Gas fry top - 1/2 1/2 grooved plate - 2 cooking zones

Gas fry top version - 1/3 g 2/3 smooth plate - 2 cooking zones

Gas fry top - grooved plate - 2 cooking zones

Dimensions 

(LxPxH) - mm.

400 x 900 x 875 (1090)

400 x 900 x 875 (1090)

400 x 900 x 875 (1090)

800 x 900 x 875 (1090)

800 x 900 x 875 (1090)

800 x 900 x 875 (1090)

800 x 900 x 875 (1090)

800 x 900 x 875 (1090)

400 x 900 x 270

400 x 900 x 270

400 x 900 x 270

800 x 900 x 270

800 x 900 x 270

800 x 900 x 270

800 x 900 x 270

800 x 900 x 270

N.

 

51BQ2910

51BQ2910

51BQ2910

 

51BQ2910

51BQ2910

51BQ2910

51BQ2910

51BQ2910

 

51BQ2910

51BQ2910

51BQ2910

 

51BQ2910

51BQ2910

51BQ2910

51BQ2910

51BQ2910

2 - CHARACTERISTICS OF THE APPLIANCES

3 - TECHNICAL DATA

The instructions contained in this manual apply to our gas
fryers in the II2H3+ category (see table on page 6).
The data plate is located on the front of the appliance and on the 

control panel. It contains all necessary reference data such as the 
name of the manufacturer, input pressure, gas type setting, etc.

0051

TIPO/TYPE

CAT/KAT

GAS/GAZ

G30

G31

G20

G25

II2H3B/P

P mbar

30

30

20

-

II2H3+

P mbar

30

37

20

-

-

II2H3+

P mbar

28

37

20

-

25

II2L3B/P

P mbar

30

30

II2ELL3B/P

P mbar

50

50

20

20

II2E+3+

P mbar

28

37

20

25

II2H3B/P

P mbar

50

50

20

-

I2E

P mbar

-

-

20

-

-

-

II2H3B/P

P mbar

30

30

II2H3+

P mbar

28

37

20

-

-

-

-

-

I3B/P

P mbar

30

30

I3+

P mbar

28

37

SE

FI

DK

CZ

SK

SI

IT

CH

PT

ES

IE

GB

GR

NL

DE

FR

BE

AT

CH

LU

EE

LV

LT

EE

LV

LT

NO

MT

CY

IS

HU

CY

MOD.

MOD.

ART.

N.

N.

Qn kW

m

3

/h

MADE IN ITALY 

Predisposto a gas: - Gas preset: - Prevu pour gaz:

Eingestelt für Gas: - Preparado para gas: - Geschuckt voor: 

V AC  

kW

Hz

THE APPLIANCE MUST BE CONNECTED IN COMPLIANCE WITH THE LAWS IN FORCE
AND INSTALLED IN A WELL-VENTILATED ROOM. READ THE INSTRUCTION MANUALS
BEFORE INSTALLING AND USING THE APPLIANCE.
THE APPLIANCE MUST BE INSTALLED BY QUALIFIED PERSONNEL.

G30/G31

28/37 mbar

G20

20 mbar

Summary of Contents for ADH3007

Page 1: ...014_03 Installation operating and maintenance instructions GAS FRY TOP 04 2006 ADH3007 ADH3008 ADH3009 ADH3010 ADH3011 ADH3012 AEH3007 AEH3008 AEH3009 AEH3010 AEH3011 AEH3012 ...

Page 2: ...nstaller 9 Running the appliance on other types of gas 9 Replacing the main burner nozzle 9 Replacing the pilot burner nozzle 9 Adjusting the low flame 9 Maintenance 10 Replacing parts page 10 Ignition plug 10 Gas tap 10 Thermocouple 10 Using the appliance Smooth grooved and chrome plates using and start up 11 First time use of the plate 11 Ignition 11 Turning the pilot burner on 11 Turning the ma...

Page 3: ...014 03 Gas fry top 3 Dimensions Gas connection Data plate G T ADH30007 ADH30008 ADH30009 ADH30010 ADH30011 ADH30012 ...

Page 4: ...014 03 Gas fry top 4 Dimensions 270 455 270 455 AEH30011 AEH30012 G G G G G Gas connection Data plate G T AEH30007 AEH30008 AEH30009 AEH30010 ...

Page 5: ... 800 x 900 x 270 N 51BQ2910 51BQ2910 51BQ2910 51BQ2910 51BQ2910 51BQ2910 51BQ2910 51BQ2910 51BQ2910 51BQ2910 51BQ2910 51BQ2910 51BQ2910 51BQ2910 51BQ2910 51BQ2910 2 CHARACTERISTICS OF THE APPLIANCES 3 TECHNICAL DATA The instructions contained in this manual apply to our gas fryers in the II2H3 category see table on page 6 The data plate is located on the front of the appliance and on the control p...

Page 6: ... gas 3 Nozzles Ø 1 100 mm Main burner G20 G30 G31 HuB 9 45 kWh m3 m3 h HuB 12 87 kWh kg kg h Nominal capacity Low flame Nominal capacity G20 G30 31 20 mbar 28 37 mbar II2H3 A m3 h kW kW No of nozzles pilot burner G20 G30 G31 15 19 15 19 0 66 0 48 1 31 0 97 165 R adjustable 120 2 x 165 R adjustable 2 x 120 36 19 2 x 36 2 x 19 13 6 2 2 6 26 6 2 6 2 12 4 2 6 2 6 5 2 Model ADH30007 ADH30008 AEH30007 A...

Page 7: ...n stallation is safe such as fitting tiles or heat reflecting ma terial to the walls Before connecting up the appliance to the gas supply check on the data plate that the appliance is fitted for the type of gas available If not consult paragraph Running the appliance on other types of gas page 9 Legal and technical requisites During assembly the following legal and technical requi sites should be ...

Page 8: ...nal capacity further you may do so using a gas meter according to the so called volu metric method It is normally enough however simply to check that the nozzles are functioning correctly Checking input pressure Fig 3 Input pressure should be measured using a gauge e g a gooseneck pipe min resolution 0 1 mbar Remove screw 22 from the pressure socket and con nect it to the tube on the gauge after m...

Page 9: ...les for the main burners and pilot light for diffe rent types of gas marked in 100ths of mm are in a case supplied with the appliance the pilot burner nozzles are marked with a code number When the appliance has been transformed or adapted recheck its functions as described in paragraph Checking the functions Replacing the main burner nozzle To change nozzle 30 pull out the fat tray and loosen the...

Page 10: ... the front pa nel of the combustion chamber then loosen the burner fixing screws The main burner can now be removed for cleaning Take care when cleaning the flame apertures Make sure you use a prong with the right diameter When reassembling the burner make sure the back slots properly into the combustion chamber Check the gas venting path make sure the gas is correctly evacuated REPLACING PARTS Al...

Page 11: ...he knob pressed down for another 15 20 seconds if the flame goes out after the knob is released start again Turning the main burner on and adjusting the temperature Fig 4 To light the main burner turn the knob on the left further to reach desidered position The thermostat has 8 positions from 1 to 7 the indicative values of temperature for each positon are the following Position degrees C 1 160 2 ...

Page 12: ...day after turning it off will keep it in perfect working order and make it last longer All steel parts should be cleaned with water and a deter gent using a damp cloth do not use abrasive substan ces or corroding detergents Do not use steel wool anywhere but on the grilling plate since this might cause rust For the same reason avoid touching the appliance with anything made of iron Do not clean an...

Page 13: ...DUE TO ITS POLICY OF CONTINUAL PRODUCT IMPRO VEMENT THE MANUFACTURER RESERVES THE RIGHT TO MAKE ANY CHANGES DEEMED NECESSARY THE MANUFACTURER CANNOT BE HELD RESPONSI BLE IF THE INSTRUCTIONS CONTAINED IN THIS MA NUAL ARE NOT OBSERVED ...