014-03 - Gas fry-top
10
the Gas Flow Setting Table (2);
- start the appliance up according to the instructions;
- after allowing the appliance to run for 45 mins., turn
the knob to low and set minimum gas flow by turning
screw (36) (to the right = gas flow decreases; to the left
= gas flow increases).
On models ADH30009 ADH30010 ADH30011 ADH30012
AEH30009 AEH30010 AEH30011 AEH30012 each burner
must be adjusted separately.
MAINTENANCE
The following maintenance programme should be carried
out at least once a year:
- Check that all the safety and setting devices are
working properly;
- Check that the burners are working properly with re-
gard to:
- ignition
- combustion safety;
- Check the functions of the appliance as described in
paragraph "Checking the functions" page 9.
If the main burner needs cleaning, proceed as follows:
a)
remove the control knobs and the fat tray; unscrew
the fixing screws and remove the control panel;
b)
unscrew hose clamp (28, Fig. 2) to disconnect the
gas vent connector from the nozzle holder;
c)
unscrew the fixing screws and remove the front pa-
nel of the combustion chamber; then loosen the burner
fixing screws.
The main burner can now be removed for cleaning.
Take care when cleaning the flame apertures.
Make sure you use a prong with the right diameter.
When reassembling the burner, make sure the back
slots properly into the combustion chamber.
- Check the gas venting path (make sure the gas is
correctly evacuated).
REPLACING PARTS
All parts must be replaced by authorised technicians
only!
To replace the following parts, first remove the control
knobs, slide out the fat tray and remove the control panel
(after unscrewing its fixing screws).
Ignition plug (Fig. 5)
The ignition plug (37) must be removed from below.
Disconnect the ignition lead, loosen the lock nut and in-
sert a new plug.
Gas tap (Fig. 3)
Loosen the gas piping and thermocouple hoses, then loo-
sen the screws fixing the gas supply to the gas ramp and
insert a new tap.
Thermocouple (Figs. 3 & 5)
Loosen the nipples fixing the thermocouple to the gas cock
and to the pilot lamp; insert the new part.
After replacing the parts, fit the control panel and its parts
back in the right order.
WARNING
Every time a replacement involving gas input parts is
made, recheck all functions and test for leakage.
35
36
34
29
37
5