CAUTION: DISCONNECT ELECTRICAL CURRENT BEFORE SERVICING

 

Please Return This Sheet to its Envelope in the Product for Future Reference

READING ERROR CODES

 

1. 

Non-Digital Readout Display Models:

 Rotate cycle selector knob to the 3 O’clock position. 

 

Digital Readout Display Models:

 Rotate cycle selector knob clockwise (3) settings from the 

Normal

 cycle option. 

2.  Press and hold the 

Select 

and

 Pause Cancel

 buttons simultaneously for six seconds. 

3.  Immediately after, press and hold the 

START 

and

 Pause Cancel

 buttons simultaneously for 4 seconds. 

4. 

Digital Readout Display Models: 

rotate the timer knob (1) click counterclockwise. The error code will appear in the digital 

display. 

 

Non-Digital Readout Display Models:

 rotate the cycle selector knob to the 2 O’clock position. The four indicator lights of 

Drying, Cool Down, Wrinkle Rid (Press Saver), 

and

 Clean Lint Filter

 will flash the number of times for the first digit of 

the code and the 

START

 indicator light will flash the number of times for the second digit. Take separate counts of each 

indicator light, then repeat to confirm in order to be accurate in identifying the proper error code. The code is obtained by 
counting the number of times the lights flash. Example E24: The four indicator lights would flash twice indicating the 2 
and the 

START

 indicator light will flash four times indicating the 4. The four indicator lights and the 

START

 indicator light 

start flashing at the same time. The control will pause for 2 seconds, then repeat the code. 

 

NOTE: 

A letter appearing in the code stands for a number higher than nine. 

A = 10 B = 11 C = 12 D = 13 E = 14 F = 15 

 Example 

Code 

E4A

: the first digit would be 4 and the second digit would be 10. If this code would appear on a washer in 

the 

Non-Digital Readout Display Models

, the four indicator lights would blink four times and the 

START

 indicator light 

would blink ten times. Troubleshoot the problem by using the chart below.  
To move on to the next code, press the 

OPTIONS

 button. 

To clear code, press the 

Select

 button. Code will be cleared when mode is exited. 

To exit this mode, simultaneously press and hold the

 Select 

and

 Pause Cancel

 buttons for six seconds. 

 

Error Code 

 

Label 

 

Description 

 

Solution 

 

E10  

General EEPROM 
Fault  

Problem with communication 
between EEPROM and the 
microprocessor.  

Clear code, exit mode and start dryer. If problem persists, replace electronic 
control.  

E11  

Checksum Error  

Problem with communications or 
memory did not check, one has 
become corrupted.  

Clear code, exit mode and start dryer. If problem persists, replace electronic 
control.  

E12  

Non fatal R/W 
error  

Problem reading or writing to the 
memory or input/output.  

Clear code, exit mode and start dryer. If problem persists, replace electronic 
control.  

E24  

Control NTC Short 
Circuit  

Control thermistor or its wiring is 
shorted.  

Remove wires from control thermistor. Measure resistance of thermistor. If 
reading is not 50 K (± 10%), replace thermistor. If reading is within 50 K (± 
10%), check wiring between thermistor and electronic control. If good, 
replace electronic control.  

E25  

Control NTC Open 
Circuit  

Control thermistor or its wiring is 
open.  

Remove wires from control thermistor. Measure resistance of thermistor. If 
reading is not 50 K (± 10%), replace thermistor. If reading is within 50 K (± 
10%), check wiring between thermistor and electronic control. If good, 
replace electronic control.  

E4A  

Program Timeout 
Fault  

The drying time has exceeded 
program time for that cycle.  

Press Pause Cancel and SELECT buttons for 6 seconds to exit test modes. 
Position cycle selector to NORMAL, temperature selector to HIGH HEAT 
and touch START. Check for anything that would extend dry times such as: 
no heat, restricted vent, blower fan blade broken or loose, dryer installed in 
closet with solid door, or bad connection in moisture sensor bar circuit or 
dirty bars. If dryer operates normally but code returns, replace electronic 
control.  

E5B  

Heater Fault (no 
heating)  

Temperature reading of control 
thermistor has not changed in a 
certain amount of time.  

Position cycle selector to NORMAL, temperature selector to HIGH HEAT 
and touch START. Measure voltage across terminals on relay RL2 (heater 
relay) on electronic control. If meter reads 240V on electric models and 
120V on gas models, replace electronic control. If meter reads zero, remove 
power from dryer. Disconnect wire going to NO terminal on the relay RL2. 
Reconnect power and measure voltage drop between terminal COM on 
relay RL2 and neutral. If meter reads zero, wire between incoming line and 
relay RL2 is open. If meter reads 120V, check the rest of the heater circuit.  

E68  

Key (button) Struck 
Fault  

One of the keys (buttons) is stuck 
closed (active).  

Enter function test mode and perform key (button) test to determine which 
button is at fault. Carefully free the and perform the test again. If button is 
free but the key struck code still exists, replace electronic control.  

E8C  

Too many trips in a 
period of time.  

The safety (high limit) thermostat 
has tripped too many times within 
a certain period of program time.  

Check for blocked lint filter, blocked exhaust, air leaks around air duct, 
broken blower fan blades, worn or loose drum seals, dryer installed in closet 
with solid doors or door seal not correctly seated.  

EAF  

Watch Dog Reset  

Microcontroller has been reset by 
internal Watchdog timer.  

Clear code, exit mode and start dryer. If problem persists, replace electronic 
control.  

 
 

Summary of Contents for 137070300B 0810

Page 1: ...e electronic control E12 Non fatal R W error Problem reading or writing to the memory or input output Clear code exit mode and start dryer If problem persists replace electronic control E24 Control NTC Short Circuit Control thermistor or its wiring is shorted Remove wires from control thermistor Measure resistance of thermistor If reading is not 50 K 10 replace thermistor If reading is within 50 K...

Page 2: ... Opening the door press in on door switch plunger and placing a finger on the both moisture sense bars at the same time will make the DAMP LED come on 4 turns Drive motor runs heat source is off Key test a When the TEMP button is pressed all the TEMP LED s should light If the Temp selector is the rotary knob and the knob is rotated there should be a key beep with each setting b When the DRYNESS bu...

Page 3: ...et sécheuse clairs de début si l erreur persiste remplacez la commande E11 Erreur De Somme Il y a un problème avec des communications ou la mémoire n a pas vérifié On est devenu corrompu Code mode de sortie et sécheuse clairs de début si l erreur persiste remplacez la commande E12 Erreur non mortelle de R W Il y avait une lecture ou une écriture de problème à la mémoire ou à l I O Code mode de sor...

Page 4: ...e chaleur est éteinte De séchage et frais vers le bas menés sont allumés et les nombres apparaissent dans l affichage montrant des lectures de sonde d humidité L ouverture de la porte enfoncez sur le plongeur de commutateur de porte et le placement d un doigt sur les les deux barres de sens d humidité en même temps feront la diminution de nombres Dans les commandes qui n ont pas un affichage de ch...

Page 5: ...a no comprobó Uno se ha corrompido Código modo de la salida y secador claros del comienzo Si persiste el error substituya el control E12 Error no fatal de R W Había una lectura o una escritura del problema a la memoria o al I O Código modo de la salida y secador claros del comienzo Si persiste el error substituya el control E24 Controle El Cortocircuito de NTC Se pone en cortocircuito el termistor...

Page 6: ...el LED HÚMEDO se adelanta vueltas 4 Funcionamientos del motor impulsor la fuente de calor está apagada Prueba dominante a Cuando la llave de la temperatura es todo el presionado la temperatura LED debe encenderse Si es el selector de temperatura la perilla rotatoria y la perilla se rota allí deben ser una señal sonora dominante con cada ajuste b Cuando la llave de la sequedad es todo el presionado...

Page 7: ......

Page 8: ......

Reviews: