Models and dimensions

page 

3

Data of appliances

4

Technical data

4-5

Operating instructions

6

Construction, equipment installed 

and safety devices

6

Assembly

6

Location

6

Legal and technical requisites

6

Installation

6

Installation procedure

6

Gas connection

6

Plumbing connection

6

Gas venting

6

Commissioning the appliance

7

Before commissioning the appliance

7

Start-up

7

Testing the power rating

7

Checking input pressure

7

Checking power rating using

the volumetric method

7

Checking power rating when using 

LP gas

7

Checking the pilot light

8

Checking the primary air

8

Checking the functions

8

Note for the installer

8

Running the appliance on other types

of gas

page  

8

Replacing the main burner nozzle

8

Pilot injector replacement

8

Adjusting the low flame

8

Maintenance

8

Replacing parts

9

Ignition plung

9

Gas tap

9

Thermocouple

9

Using the appliance

10

First-time use of the appliance 

10

Ignition

10

Turning the pilot burner on

10

Turning the main burner on and adjusting

the temperature

10

Turning the appliance off

10

Turning the appliance off during 

normal operation

10

Turning the appliance off 

in an emergency

10

What to do if something goes wrong or if 

not using the appliance for a long time

10

Taking care of the appliance

frequency of maintenance

11

Daily cleaning

11

Precautions during use

11

Protection of stainless steel

11

Warning

12

INDEX

052-03 - Gas pasta cooker

2

Summary of Contents for ABE0001

Page 1: ...052_03 Installation operating and maintenance instructions GAS PASTA COOKER 03 2006 ABE0001 ACE0005...

Page 2: ...ons 8 Note for the installer 8 Running the appliance on other types of gas page 8 Replacing the main burner nozzle 8 Pilot injector replacement 8 Adjusting the low flame 8 Maintenance 8 Replacing part...

Page 3: ...Gas control knob Piezo electric lighter Water inlet Gas connection Models and dimensions 55 21 600 400 E F 55 655 300 B D A C F 55 21 600 400 E F 55 700 300 B D A C F ABE00001 600 x 650 x 300 weight...

Page 4: ...ar 30 30 II2H3 P mbar 28 37 20 I3B P P mbar 30 30 I3 P mbar 28 37 SE FI DK CZ SK SI IT CH PT ES IE GB GR NL DE FR BE AT CH LU EE LV LT EE LV LT NO MT CY IS HU CY MOD MOD ART N N Qn kW m3 h MADE IN ITA...

Page 5: ...l power Connection pressure Methane gas 2H Liquid gas 3 Gas connection values Methane gas 2H Liquid gas 3 Nozzles 1 100 mm Main burner G20 G30 G31 HuB 9 45 kWh m3 m3 h HuB 12 87 kWh kg kg h Nominal ca...

Page 6: ...quisites During assembly the following legal and technical re quisites should be adhered to relevant national legislation local building and fire safety regulations worksheet Technical rules for insta...

Page 7: ...Flow Regulation table If you wish to check the nominal capacity further you may do so using a gas meter according to the so called volumetric method It is normally enough however simply to check that...

Page 8: ...pted recheck its functions as described in paragraph Checking the functions Main burner injector replacement Fig 1 To replace the injector 30 dismount the front panel Dismount the holding injector col...

Page 9: ...tion lead loosen the lock nut and insert a new plug Gas tap Fig 3 Loosen the gas piping and thermocouple hoses then loosen the screws fixing the gas supply to the gas ramp and insert a new tap Thermoc...

Page 10: ...nob to the right until it is on high or else continue until it reaches low the heating capacity must be set between these two positions TURNING THE APPLIANCE OFF Turning the appliance off during norma...

Page 11: ...e of fibrous synthetic material rubbing in the direction of the satin finish Rinse and dry thoroughly Never use wire wool for cleaning stainless steel or leave it in contact with the steel as very sma...

Page 12: ...DUE TO ITS POLICY OF CONTINUAL PRODUCT IMPRO VEMENT THE MANUFACTURER RESERVES THE RIGHT TO MAKE ANY CHANGES DEEMED NECESSARY THE MANUFACTURER CANNOT BE HELD RESPONSI BLE IF THE INSTRUCTIONS CONTAINED...