mastro ABB0001 Installation, Operating And Maintenance Instructions Download Page 5

054-03 - Gas Bain-marie

5

Primary air distance “A”

Methane gas G20

Liquid gas G30/G31

TABLE 1

Model

Category

Construction type

Air necessary for combustion

Nominal thermal power

Minimum thermal power

Connection pressure

Methane gas 2H

Liquid gas 3+

Gas connection values

Methane gas 2H

Liquid gas 3+

Nozzles Ø 1/100 mm

Main burner

G20

G30/G31

(HuB = 9.45 kWh/m

3

)  m

3

/h

(HuB = 12.87 kWh/kg)  kg/h

Nominal capacity

Low flame

Nominal capacity

Low flame

G20

G30/31

20 mbar

28/37 mbar

 

 

II2H3+

A

m

3

/h

kW

kW

No. of nozzles, pilot burner

G20

G30/G31

-

-

115R

-

75

-

5

2.4

-

-

-

8

4.0

-

0.254

0.188

0.423

0.313

35

20

145

-

100

-

35

20

ABB00001
ACB00001

ADB00001
AEB00003

Summary of Contents for ABB0001

Page 1: ...054_03 Installation operating and maintenance instructions GAS BAIN MARIE 04 2006 ABB0001 ADB0001 ACB0001 AEB0003...

Page 2: ...pilot light 8 Checking the primary air 8 Checking the functions 8 Note for the installer 8 Running the appliance on other types of gas 8 Replacing the main burner nozzle 8 Adjusting the pilot burner 8...

Page 3: ...300 25 400 142 15 1 2 GC 1 2 GC 655 ACB00001 1085 875 700 400 35 1 2 GC 1 2 GC 25 75 155 208 510 300 25 400 142 15 1 2 GC 1 2 GC 700 430 1 2 GC 1085 1 2 GC 510 1 2 GC 1085 875 900 400 3 4 GC 3 4 GC 2...

Page 4: ...TYPE CAT KAT GAS GAZ G30 G31 G20 G25 II2H3B P P mbar 30 30 20 II2H3 P mbar 30 37 20 II2H3 P mbar 28 37 20 25 II2L3B P P mbar 30 30 II2ELL3B P P mbar 50 50 20 20 II2E 3 P mbar 28 37 20 25 II2H3B P P mb...

Page 5: ...ssure Methane gas 2H Liquid gas 3 Gas connection values Methane gas 2H Liquid gas 3 Nozzles 1 100 mm Main burner G20 G30 G31 HuB 9 45 kWh m3 m3 h HuB 12 87 kWh kg kg h Nominal capacity Low flame Nomin...

Page 6: ...mm around the si des and back should be allowed Place table top appliances on a table or shelf in fla me proof material Before connecting up the appliance to the gas sup ply check on the data plate th...

Page 7: ...ge 8 To start the appliance up see the instructions for regular use Testing the power rating Use the specific nozzles for the rated output see table 1 in assembly instructions Working tolerances for t...

Page 8: ...ns to the room housing the appliance may affect the combustion air supply Once the alterations have been completed the appliance and its functions should be thoroughly checked Running the appliance on...

Page 9: ...remove the control panel after unscrewing its fixing screws It is advi sable to empty the tank Valve 1 Fig 2 Unscrew the fitting 3 16 21 17 and loosen the fixing screws The valve may now be removed a...

Page 10: ...054 03 Gas Bain marie 10 ABB00001 ACB00001 10 13 12 10 13 12 38 37 34 36 35 ADB00001 AEB00003 10 13 12 3 6...

Page 11: ...h the hole provided for that purpose Lighting the main burner of the tank To ligth the main burner turn the knob to the posi tion required The 7 positions correspond approxi mately to the following te...

Page 12: ...water whether direct or pressurised Allow the machine to cool down before cleaning Giving the appliance a thorough clean every day after turning it off will keep it in perfect working or der and make...

Page 13: ...DUE TO ITS POLICY OF CONTINUAL PRODUCT IMPRO VEMENT THE MANUFACTURER RESERVES THE RIGHT TO MAKE ANY CHANGES DEEMED NECESSARY THE MANUFACTURER CANNOT BE HELD RESPONSI BLE IF THE INSTRUCTIONS CONTAINED...