background image

 

Page |  - 5 -© Page |  - 5 -  © Copyright Mastip Technology Limited. Information subject to alteration. V2.0    www.mastip.com

 

 

  Sequential Injection Controller                             SC8 

time and wait for the next injection signal. 

7)

 

If the injection signal is off before the open time passed, the controller will close the gate 
output, and reset the delay time & open time. 

 

 

Mode AB: 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1)

 

When the controller receives the injection signal  (t1),  the indicator A is lit up and delay 
time1 begins. 

2)

 

The controller counts down the delay time1 and displays it on DEL display unit. 

3)

 

At the end of delay time1, the controller opens the gate output, counts the open time1 and 
shows it on OPEN display unit. 

4)

 

At the end of open time1, the controller closes the gate output. 

5)

 

Then the indicator B is lit up and delay time2 begins. 

6)

 

At the end of delay time2, the controller opens the gate output, counts the open time2 and 
shows it on OPEN display unit. 

7)

 

At the end of open time2, the controller closes the gate output. 

8)

 

When the injection signal is off (t2), the controller resets the delay time & open time, and 
shows delay time 1 & open time 1 on DEL & OPEN display units.   

9)

 

If the injection signal is off before the delay time1 passed, the controller will reset the 
delay time and wait for the next injection signal. 

10)

 

If the injection signal is off before the open time1 passed, the controller will close the gate 
output, and reset the delay time and open time. 

11)

 

  If the injection signal is off before the delay  time2 passed, the controller will reset the 
delay time and open time, then wait for the next injection signal. 

12)

 

  If the injection signal is off before the open time2 passed, the controller will close the   
gate output, and reset the delay time and open time.

 

 

Summary of Contents for MetiCom SC8

Page 1: ...SC8 Sequence Injection Controller User Guide Ver 2 0...

Page 2: ...s been modified or integrated with other products when the effect of such modification or integration increases the time or difficulty of servicing the product This warranty excludes replacement of fu...

Page 3: ...perating condition 0 55 32 131 10 80 non condensing Storage temperature 20 70 4 158 4 Faceplate 1 Gate number Gate1 Gate8 2 Delay time display Shows delay time of corresponding gate green 3 Open time...

Page 4: ...he gate selected 15 Power key Used to turn on off the controller Power indicator Blinks after connected power and lights after the controller is turned on 16 Operating mode indicator Indicates the ope...

Page 5: ...the counted open time is showed on OPEN display unit until the next injection signal comes on 6 If the injection signal is off before the delay time passed the controller will reset the delay time and...

Page 6: ...elay time2 begins 6 At the end of delay time2 the controller opens the gate output counts the open time2 and shows it on OPEN display unit 7 At the end of open time2 the controller closes the gate out...

Page 7: ...g off means to shut off this gate 3 Press or to select the gate and repeat step 2 At the same time the operating mode setting is saved 4 Press ENTER key to save the setting and exit the procedure Sele...

Page 8: ...l gates output gate indicator lights until the OPEN key is released Open the selected gate output manually 1 Press or to select the gate the corresponding gate light blinks 2 Press OPEN key and hold o...

Reviews: