Maintaining NC-3000
25
Calibration
The sensors can be easily calibrated to ensure best performance:
Turn the unit off and on again.
While the initializing indicator is running, press the keys "Cur" and "Start"
together and hold until the display showing calibration menu.
Select the desired submenu.
a.
Optical – to calibrate the IR sensors.
b.
Motor –to calibrate the motor speed.
Calibration Menu
Optical calibration
Install the calibration paper (white slip) supplied with this manual and press
F3
NC-3000 Series calibrates the sensors automatically.
The display shows the result accordingly,
Any number of sensors = Repeat calibration
OK = Calibration done
On the process of calibration
Repeat step 2~3, until the display shows "OK",
After complete the calibration of white slip, install the black slip and repeat
the step 2~3 until the display shows "OK",
Once you completed the calibration, just turn the unit off, NC-3000 Series
runs in normal mode the next time you turn it on.
Optical Calibration Failure
Optical Calibration Success
Motor Calibration