Please note that regular maintenance of the system in general durability.
Periodic maintenance of the filters
The maintenance intervals recommended periodic maintenance are listed below.
GROUP TO CHECK
FREQUENCY OF CONTROL
OPERATIONS TO DO
Sportello contenitore di
decantazione
When checking the filters
Drain off and blow with
compressed air
Prefilter cartridge
When the extraction is low
Blow with compressed air
Microfilter cartridge
About every 300-500 hour
Change
Carbons
When the expelled air has bad
smell
Change
The filters should be replaced after 2 or 3 cleanings.
The filters, when replacing, be disposed of according to regulations.
For the replacement of the filters follow as described previously.
Non-ordinary interventions
Involves repair and replacement of one or more system components that normally are necessary after years
of successful operation and does not alter the characteristics of the machine.
In case of substantial changes, the manufacturer cannot be held responsible for any dangers that might arise.