INSTALLING & CLEANING CARTRIDGE FILTER
16
WET/DRY VACUUM WITH TWO-STAGE MOTOR - 054-0241-8
5
6
1
2
3
4
Installing Cartridge Filter
1. Check that the power cord is disconnected from the outlet. (Fig. 1)
2. Remove power head and place in upside down position.
3. Install the cartridge filter over the filter cage with the flat end of the filter towards the vacuum power
head. Carefully push filter on until it stops against the power head. (Figs. 2 & 3)
4. Place filter retainer on top of cartridge filter over the raised lip and tighten down by turning retainer
clockwise. Do not over tighten. (Figs. 4 & 5)
Removing and Cleaning Cartridge Filter
1. Unlock and remove the filter retainer by turning retainer handle counter-clockwise.
2. Carefully hold and pull the cartridge filter up for removal. (Fig. 6)
3. Clean the cartridge filter by gently tapping or brushing dirt off. Cleaning should not be done indoors in
living areas. For optimal performance a new filter is recommended.
4. Install cleaned or new filter as instructed above in steps 2 and 3 of Installing Cartridge Filter.
5. Wet filters should be removed and allowed to air dry for 24 hours before installing onto the filter cage.