background image

Page 8 

7.  OPERATING INSTRUCTIONS

JUMP STARTING A VEHICLE

IMPORTANT:

 Using the jump starter with-

out a battery installed in the vehicle will 

damage the vehicle’s electrical system.

1. 

Turn the ignition OFF.

2. 

Lay the DC cables away from any fan 

blades, belts, pulleys and other mov-

ing parts.

3. 

For a negative-ground vehicle (as 

in most vehicles), connect the jump 

starter’s POSITIVE (RED) clamp to 

the POSITIVE (POS, P, +) battery post. 

Next, connect the NEGATIVE (BLACK) 

clamp to the vehicle chassis or engine 

block, away from the battery. 

4. 

For a positive-ground vehicle, con-

nect the jump starter’s NEGATIVE 

(BLACK) clamp to the NEGATIVE 

(NEG, N, -) battery post. Next, connect 

the POSITIVE (RED) clamp to the vehi-

cle chassis or engine block away from 

the battery.

5. 

Press the ON/OFF switch to turn on 

the jump starter. The green 

Ready 

LED will light.

6. 

It is best to wait 30 seconds after 

clamp connection to attempt to start 

the vehicle. Crank for up to 5 seconds. 

If engine does not start, wait 30 sec-

onds before cranking again.

7. 

After the engine starts, press the ON/

OFF switch to turn the jump starter off, 

and then disconnect the black clamp (-) 

and the red clamp (+), in that order.

8. 

Recharge the unit as soon as possible 

after each use.

USING THE USB PORT 

The USB port provides up to 2.4A at 5V DC.

1. 

Ensure the battery clamps are securely 

clipped on the storage holders.

2. 

Flip the ON/OFF power switch to turn 

the unit ON.

3. 

Plug your device into the USB port.

4. 

Turn on the USB device.

5. 

When finished using the USB port, 

turn the switch to the OFF position.

6. 

Recharge the unit as soon as possible 

after each use.

USING THE WORK LIGHT

1. 

Position the jump starter on a flat, 

stable surface near the intended work 

area.

2. 

Ensure the battery clamps are securely 

clipped on the storage holders.

3. 

Flip the ON/OFF power switch to the 

ON position.

4. 

Press the 

Battery Status/Light

 button 

on the front of the unit for 0.75 sec-

ond, to turn on the work light. 

5. 

When finished using the work light, 

press the button for 0.75 second, to 

turn off the work light. 

6. 

Recharge the unit as soon as possible 

after each use. 

ENERGY SAVING MODE

If the unit is not used after the ON/OFF 

power switch is turned on, the unit will go 

into Energy Saving mode after 10 minutes 

to prevent battery discharge. Follow these 

steps to use any function after Energy Sav-

ing mode:

1. 

Press the ON/OFF power switch to 

turn the unit ON.

2. 

The Green 

Ready/Fail

 LED will light.

3. 

After 10 minutes, the USB port and 

Battery Status/Light

 function will turn 

off.

4. 

After 10 minutes, the Green 

Ready/

Fail

 LED will turn off.

5. 

Press the 

Battery Status/Light

 button 

once. The unit is now ready for check-

ing the battery status and using the 

jump starter, USB and work light.

Summary of Contents for 260-9516

Page 1: ...Reduce The Risk Of Injury User Must Read And Understand Operator s Manual Save These Instructions For Future Reference 260 9516 0099002184 02 1000 Peak Amp Lithium Ion Jump Starter and USB Power Sour...

Page 2: ...age 5 Personal Safety Precautions Page 5 Features Page 6 Specifications Page 7 Replacement Parts Page 7 Charging the Internal Battery of the Jump Starter Page 7 Operating Instructions Page 8 Maintenan...

Page 3: ...pe of current Direct current Type or characteristic of current Class II construction Double insulated construction Read the operator s manual To reduce the risk of injury read and understand the opera...

Page 4: ...lt in electric shock fire and or serious personal injury SYMBOL MEANING SAFETY ALERT SYMBOL Indicates DANGER WARNING or CAUTION May be used in conjunction with other symbols or pictographs Failure to...

Page 5: ...1 11 To prevent arcing never allow the clamps to touch together or to con tact the same piece of metal 1 12 Use of an attachment not recom mended or sold by the jump starter manufacturer may result in...

Page 6: ...ide reasonable protection against harmful interference in a res idential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance w...

Page 7: ...rter will fully charge in 3 4 hours NOTE Use a 2A USB charger not included or a 2A USB charging port to quickly recharge the jump starter Using a charger with less than 2A will increase charge time 1...

Page 8: ...des up to 2 4A at 5V DC 1 Ensure the battery clamps are securely clipped on the storage holders 2 Flip the ON OFF power switch to turn the unit ON 3 Plug your device into the USB port 4 Turn on the US...

Page 9: ...on the handle Do not store the clamps clipped together on or around metal or clipped to the cables 9 TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION The jump starter won t jump start my car Clamps ar...

Page 10: ...ery low voltage protection Flashing LED alternates between Green and Red Reverse charging protection Red LED flashing and buzzer sounds twice per second Reverse polarity protection Red LED flashing an...

Page 11: ...ise This warranty 1 excludes expendable parts including but not limited to blades brushes belts bits light bulbs and or batteries 2 shall be void if this product is used for commercial and or rental p...

Page 12: ...2020 Menard Inc Eau Claire WI 54703 05 2020...

Reviews: