OPERATING MANUAL
ASSEMBLED BY:
A-1299-5136
Page 3 of 8 Printed in USA
Edition 03
(US and Canada) Toll Free 1-800-MASTERFLEX
•
1-800-637-3739
(Outside US and Canada) 1-847-549-7600
•
1-847-381-7050
www.masterflex.com
•
The MASTERFLEX
®
I/P
®
High Performance Pump Head delivers in excess of 17 L/min flow at normal
MASTERFLEX operating speeds and pressures. It is designed for optimal pumping in the clockwise direction.
There are two mounting positions. Tubing entry and exit are either on the left side or on top of the pump when
mounted on a MASTERFLEX
®
I/P
®
drive. The pump will operate with any MASTERFLEX
®
I/P
®
drive that
accepts two or more Pump Heads. However, maximum operating pressure depends on the drive and tubing
material selected, as shown below.
SETUP AND OPERATION
Pump Drive Compatibility
The High Performance Pump Head has a standard shaft interface to accommodate MASTERFLEX
®
I/P
®
Pump
Drives.
Mounting Pump Head to Drive
1.
Check that pump drive is turned OFF.
2.
Make sure the plastic tang boot (see Figure 4) is installed on the pump shaft tang. (Operation without the
boot could cause damage to the pump shaft.)
3.
Align pump shaft tang with slot in motor shaft.
4.
Secure pump to pump drive with the four mounting screws (furnished).
a.
For left side tubing entry and exit, use round mounting holes.
b.
For top tubing entry and exit, use hexagonal mounting holes.
c.
When using MASTERFLEX console drives, 77410 and 77411 series, mount the pump
according to Figure 1. Use the holes labeled “A” for left tubing entry/exit pump orientation;
use holes labeled “B” for top entry/exit orientation.
Selecting Tubing
Pumps accept only I/P
®
70, I/P
®
88 and I/P
®
89 tubing. Use only MASTERFLEX tubing which is surface printed
with the tubing designation.