Tub Pop-up Drain Stopper Adjustments & Maintenance 

 

Drain Brake Adjustment

: Reference drawing 800966. Locate both¼ - 20 x 3/8 SS set screws (Item 18) in the bushing 

(Item  29)  behind  the  handle  flange.  Adjust  brake  tension  by  slightly  tightening  both  set  screws  with  a  1/8"  Allen 
wrench. Do not over tighten. Tighten just enough to prevent drain pop-up from closing while tub is draining. 

 

Drain  Pop-Up  Stopper  Replacement  Directions

:  Reference  drawing  800996.  Open  drain.  Back  off  the  SS  jam  nut 

(Item  4)  by  turning  it  clockwise.  Remove  damaged  or  worn  out  drain  stopper  (item  2),  by  turning  it  counter 
clockwise. Close drain. Thread new stopper clockwise onto the drain stem (Item 8) as far as it will go. Open drain. 
Turn stopper again ¾  turn clockwise. 

 

Drain  Pop-Up  Stopper  Base  Position  Adjustment:

  Reference  drawing  800996.  If  needed,  the  drain  stem  can  be 

adjusted to extend or retract further by adjusting the cable casing (Item 32) anchor position on the handle control 

box (Item 25). Open the drain. Remove the two anchor screws in the inside ends of the control box ( or Items 19 & 
38). Pull the control box away from the side of the tub. Mark the position of the cable in relation to the "P" clips 
(Item 15). Loosen the two 10-32 nuts (item 33) on the "P" clips. Reposition the cable away from the cable linkage arm 
(Item  31)  to  cause  the  drain  stem  to  retract  more.  Adjust  to  desired  position.  Tighten  nuts  on  "P"  clips.  Reinstall 
control box in tub with anchor screws ( or Items 19 & 38). 

 

Drain Basket Replacement Directions:

 Reference drawing 800996. Remove drain stopper following above directions. 

Insert special tool in drain basket (Item 12) slots. Clamp on center of special tool with a pair of Vice Grips. Remove by 
turning counter clockwise. Clean old seal material away from drain hole. Be careful not to break the adhesive sealant 
holding the drain shoe (Item 13) to the tub bottom. Apply plumbers putty around beveled lip of drain basket. Using 
the special tool, screw the drain basket back into the drain shoe until firm. Do not over tighten. Replace the drain 
stopper following the direction above. 

Drain Cable Replacement 

1.

 

Pen  drain.  Remove  front  lower  service  access  panel  (Item  95,  drawing  804325)  on  tub.  Next,  reference  drawing 

800996.  Back  off  set  screw  (Item  18)  from  drain  cable  end  (Item  21  ).  Snip  off  end  of  wire  extending  from  cable 
casing. Mark the position of the cable casing (Item 32) in relation to the "P" clip (item 15). Loosen the nut (Item 9) on 
the "P" clip. 

2.

 

Remove the anchor screws (or Items 19 & 38) inside the two ends of the handle control box (Item 25). Pull the box 
away from the side of the tub. Disconnect the cable linkage arm (Item 31 ), then remove the wire from the hole in 
the linkage arm. Mark the cable casing location in relation to the "P" clips (Item 15). Loosen the nuts (Item 33) on the 
"P" clips. Next, pull the wire from inside on the cable casing. Insert the new replacement wire inside the cable casing. 
Insert the wire in the hole in the cable linkage arm. Re-anchor the cable housing (in the same location) to the drain 
handle control box by tightening the nuts on the "P" clips. Reinstall the drain handle control box in the tub. 

3.

 

Re-insert the wire on the drain shoe (Item 13) end into the drain cable end (Item 21 ). Secure by tightening the set 
screw in the drain cable end. Re-anchor the cable casing by tightening the nut on the "P" clip in this location. Test to 
make  sure  the  drain  opens  and  closes  correctly.  Make  adjustments  as  required.  Reinstall  the  front  service  access 
cover. 

 

 

Summary of Contents for MB-80

Page 1: ...Integrity Bath Model MB 80 Maintenance Manual For All Maintenance Procedures Follow the Directions in this Manual...

Page 2: ...o their application and the durability requirements of the healthcare industry It is recommended that the bathing system be inspected and preventative maintenance performed using the following schedul...

Page 3: ...or and swing out of way Remove SOCKET HEAD CAP SCREWS from ROLLER BRACKET Save SS SPACERS between BRACKET and DOOR HINGE MOUNTING BASE b Add SS SPACER to each spacer group Reinsert SOCKET HEAD CAP SCR...

Page 4: ...STIC WEDGE index is on top of the PLASTIC BUSHING b Position ALUMINUM MOUNTING BLOCK to insure even engagement of PLASTIC WEDGE Check the clearance of the bottom edge of the DOOR See drawing below You...

Page 5: ...the SLIDE END CAP item 3 in drawing 803966 It should not be worn through on the side that contacts the outer surface of the door To replace 1 Remove old end cap 2 Clean any residual adhesive 3 Smear a...

Page 6: ...bove directions Insert special tool in drain basket Item 12 slots Clamp on center of special tool with a pair of Vice Grips Remove by turning counter clockwise Clean old seal material away from drain...

Page 7: ...itch Item 72 5 Disconnect the air tubing Item 79 from the switch nipple 6 Remove spade connectors from switch terminals noting which was connected to which terminal 7 Remove nut holding the switch in...

Page 8: ...the replacing the cartridge 2 Using a utility knife gently pry off the cap 6 that is located on top of the thermostatic control valve handle 7 3 Using a Philips screwdriver remove the screw 8 and the...

Page 9: ...0 798 5867 FAX 402 563 9102 www mastercarebath com GEN II MIXING VALVE DIAGRAM ITEM NO DESCRIPTION QTY 1 THERMOSTATIC VALVE 1 2 CARTRIDGE REPLACE THERMOSTATIC 1 3 O RING 3 4 HUB 1 5 SETTING RING 1 6 C...

Page 10: ...d or cracked replace Check aeration body tightness against tub floor If loose tighten until 0 ring part 36000 under the shoulder seals With tub full of water and air on Check area around aeration gask...

Page 11: ...Integrity Bath Model MB 80 Maintenance Manual 07 06 15 Page 11 of 16 2071 14 th Ave Columbus NE 68601 800 798 5867 FAX 402 563 9102 www mastercarebath com VARIABLE SPEED BLOWER ENTREE 500105...

Page 12: ...with the pump operation will turn on when the pump operation is activated The middle Red LED is for Bath Oil The bottom Red LEO is for Shampoo Priming Operation Remove the empty one gallon container o...

Page 13: ...ate Is the check valve inside the metering knob clogged To fix remove four screws to disassemble Inspect and clean ball spring and 0 ting Lubricate with liquid soap and reassemble Check the orifice to...

Page 14: ...es but doesn t stay positioned when releasing lever Rotate clevis mount counter clockwise one turn and reinstall Rotate another turn if chair still doesn t lock in place Replacement 1 Support chair ba...

Page 15: ...w it to shut off on its own 2 Turn the scale back on again by pushing the ON ZERO BUTTON After the scale turns back on push the ON ZERO BUTTON and continue to hold down while also pushing the LBS KG B...

Page 16: ...ng Assembly Door Handle Assembly 301176 804220 Console Plumbing Assembly 804221 Console Plumbing Pre assembly 804225 Reservoir Assembly 804245 Drain Shoe Assembly Integrity Reservoir 804255 Plumbing A...

Reviews: