The Models MP-MBA-45T-1 and MP-MBA-60T-1 has been tested 

and certified by the Water Quality Association according to NSF/ANSI 44 
for the specific performance claims as verified and substantiated by test 
data as follows:                  

                                                                                                     

  

 

MP-MBA-45T-1

    

Rated Efficiency:   4590 Grains per pound of salt 

                                    5.25 lbs salt:   24.1 Kg Capacity 
                                    13.5 lbs salt:   47.3 Kg Capacity 
                                    22.5 lbs salt:   54.6 Kg Capacity 
                    Rated Service Flow:   10.0 GPM @ 14.5 psi pressure drop  

                                   

Resin:    1.5 CU FT cation exchange resin 

MP-MBA-60T-1    

Rated Efficiency:   4250 grains per pound of salt 

                                      5.0 lbs salt:   21.3 Kg Capacity 
                                    12.0 lbs salt:   39.8 Kg Capacity 
                                    20.0 lbs salt:   46.0 Kg Capacity 
                    Rated Service Flow:   15.0 GPM @ 14 psi pressure drop 

                             

        Resin:    2.0 CU FT cation exchange resin 

Water Softener Positioning: 

 

1.  Place water softener in desired position, far enough from walls 

and other obstructions to allow for servicing the unit. 

 

2.  Place the water softener within reasonable access to a grounded 

115V/60 HZ  circuit and a legal drain line connection.  

 
                   

Water Softener Tank Loading: 

(MP-MBA-45T-1 and the MP-MBA-60T-1are preloaded at the factory) 

1.  Remove yellow caplug from top of tank.  DO NOT CUT white 

riser tube.  Tube was prefitted at the factory. 

2.  Center the distributor and make sure it is resting on the bottom of 

the tank.  The top of the distributor pipe will extend above the top 
of the tank (this was prefitted at the factory). 

3.  Cover the top opening of the distributor pipe before filling the 

tank with media. 

4.  Pour the C-800 provided with the unit into the top of the tank.  

See page one for your specific model number unit to determine 
the amount of media to load into the mineral tank. 

5.  Remove the material used to cover the top opening of the 

distributor pipe. 

Summary of Contents for MP-MBA-45T-1

Page 1: ...Installation and Operation Manual MP MBA 45T 1 60T 1 75T 1 with the 268 762 Logix Control Valve MASTER Water Conditioning Corp www masterwater com July 2006 ...

Page 2: ...ogix 762 Electrical Connection Filling Softener with Water Details for Filling Softener Tank with Water 8 Filling Softener with Water Continued Details for Filling Softener Tank with Water Continued Logix 762 Control Valve Timer Settings Setting the Timer 9 Logix 762 Control Valve Timer Settings Continued Setting the Timer Continued 10 Logix 762 Control Valve Timer Settings Continued Setting the T...

Page 3: ...alve with an impulse meter to initiate regeneration The Logix Valve is constructed of non corrosive Noryl material and is rated at a maximum working water pressure of 100 psi This softener includes a manually operated bypass device which enables the softener to be isolated from the water service lines for manintence and service while maintaining the continuity of the untreated water supply It uses...

Page 4: ... water softener in desired position far enough from walls and other obstructions to allow for servicing the unit 2 Place the water softener within reasonable access to a grounded 115V 60 HZ circuit and a legal drain line connection Water Softener Tank Loading MP MBA 45T 1 and the MP MBA 60T 1are preloaded at the factory 1 Remove yellow caplug from top of tank DO NOT CUT white riser tube Tube was p...

Page 5: ...upward Place gasket into nut and secure 1 copper or pvc tail piece with a nut Repeat the procedure for the outlet connection DO NOT OVERTIGHTEN THE NUT Figure 2 2 The control valve s drain connection is 3 4 npt and is located on the back of the control valve 3 Turn the control valve upside down and ensure that the control valve o rings are in place Use silicone lubricant on the o rings 4 Place the...

Page 6: ...vent instructions 3 The drain line connection is located on the back of the valve as you face the timer It is recommended you install a union on the drain line for servicing The drain line must be of adequate size to allow for full regeneration flow FIGURE 3 The control valve drain connection is 3 4 npt Never decrease the drain piping size to below Maximum drain line length is 30 feet Maximum drai...

Page 7: ...k or water meter if its public water supply Master Water Conditioner Brine tank Air Gap Drain Overflow fitting to floor drain gravity Treated water Untreated to outside 224 Shoemaker Rd Pottstown PA 19464 Typical Piping Layout Temperature MAX 120 F MIN 34F Pressure MAX 100 PSI MIN 20 PSI Electrical 115V 60 HZ ...

Page 8: ...electrical service provides power 24 hours per day We recommend installing a surge protector to protect unit from power surges which are not covered by warranty Brine Tank 1 The brine tank should be located directly beside the water softener mineral tank 2 Connect the 3 8 poly tubing to the 3 8 white elbow compression fitting located on the right side of the Logix control valve See Figure Below Th...

Page 9: ... electrical outlet 4 The screen will now change between the Gallons Remaining to Regeneration and the current Gallons per Minute gpm flow rate Filling Water Softener with Water Figure 4 1 Push the FOR REGENERATION button Figure 4 on the controller down for 5 seconds This will initiate a manual regeneration You will notice a flashing hour glass during regeneration The controller will indicate that ...

Page 10: ...ltaneously press the SET and UP buttons on the controller for 1 second then release the motor will advance the cam to C3 Repeat this procedure until the timer enters the C7 FAST RINSE position The softener will go through the rinsing cycle and then automatically advance to BRINE REFILL C8 and fill the brine tank with the proper amount of water 4 The control valve will advance to C0 REGENERATION CO...

Page 11: ...e screen will show the Regeneration Day Override in blinking numbers 2 To change the number use the UP or DOWN arrows 3 Press the SET button Salt Amount Setting 1 Press the SET button The screen will show the Salt Amount as pounds in blinking numbers 2 DO NOT CHANGE THE NUMBER 3 Press the SET button Softening Capacity Setting 1 Press the SET button The screen will show the Capacity as grains in bl...

Page 12: ...re the drain line connection meets all plumbing codes and that the drain line size can handle the backwash flow rate of the softener 3 Make sure the Inlet and Outlet on bypass valve are open 4 Make sure the control valve timer is plugged into an electrical outlet with power 24 hours per day 5 Check all piping for leaks ...

Page 13: ...nual bypass valve Leak at riser pipe seal Insure that riser pipe is properly sealed at o ring seal Inspect pipe for cracks Insufficient brine Check brine float height and clean assembly if necessary Check flow rate capabilities of safety float and air check assembly Plugged injector or injector screen Inspect and clean injector and or injector screen Symptom No Brine Draw Possible Cause Solution P...

Page 14: ...to height of valve Damaged valve disk Replace all valve disks Partially restricted drain line Remove restriction Symptom Insufficient Refill to Brine Tank Possible Cause Solution Brine refill control Remove and clean Restricted flow rate in brine line Check flow rate capabilities of the safety float aircheck assembly Symptom Excessive Water in Brine Tank Possible Cause Solution Plugged drain line ...

Page 15: ...eral bed with cleaner Slots in riser pipe or laterals are filled with resin fines Inspect and clean distributor pipe slots as needed Symptom Salt in Water to Service After Regeneration Possible Cause Solution Injector is too small for system size Install correct injector Brine draw time excessively long due to low water pressure Increase water pressure above 25 psig 172 kPa minimum Restricted drai...

Page 16: ...14 ...

Page 17: ...15 ...

Page 18: ...16 ...

Page 19: ...17 ...

Page 20: ...ll be void in the event of damages from external sources or where the conditioner has been operated at pressure in excess of 100 pounds per square inch or at a temperature greater than 100 degrees F or less than 32 degrees F Incidental costs or consequential damages are not covered by this warranty All defective parts shall be returned prepaid to Master Water Conditioning Corporation for inspectio...

Reviews: