background image

Dear Customer, thank you for purchasing a MASTER S.p.A. product. This guide contains all the information you will need concerning the use of this product. Read the instructions
carefully and keep them for further consultation. The receiver module MIR is specially designed for the control of a tubular motor with

. All other use beyond

the field defined by MASTER S.p.A. is forbidden. This, as well as the breach of the instructions given in this guide, shall release MASTER S.p.A. from any liability and shall annul the
product warranty.

mechanical limit switches

At the end of the product life cycle, dispose of the device in
compliance with local regulations. This product could
contain substances that are harmful to human health and
the environment: do not dispose of the product in domestic
waste.

Disposal

Do not use radio systems in places with strong interference (for example, near police stations, airports, banks, hospitals). It is in any
case advisable to carry out a technical inspection prior to installing any radio system in order to identify possible sources of
interference. Radio systems can be used where any disturbances or malfunction of the transmitter or receiver do not constitute a
risk factor, or if such factor is eliminated using appropriate safety systems. The presence of radio devices working at the same
transmission frequency (433.42 MHz) may interfere with the radio receiver and reduce the range of the system, limiting
functionality.

Notes on radio systems

01. WARNINGS

Incorrect installation can cause serious injuries

Keep these instructions for future maintenance work and disposal of the product

All the product installation, connection, programming

and maintenance operations must be carried out only by a qualified and skilled technician, who must comply with laws, provisions, local regulations and the instructions given on this
manual

The electrical wiring must comply with current IEC standards

Some applications require «hold-to-run» operations and can exclude the use of radio controls or require

particular safety devices

To prevent potentially dangerous situations, check the operating condition of the roller shutter/awning regularly

01.1 Warnings for safety

Check that the package is intact and has not suffered damages in transit

A heavy knock and the use of unsuitable tools can cause damage

Do not pierce or tamper with the box in any

way. Do not modify or replace parts without the manufacturer’s permission

The antenna cable carries line voltage. Do not cut the antenna cable as this would be dangerous. If the

antenna cable is damaged, replace the product

If there are several radio appliances in the same system, they must not be less than 1,5 m apart

The product is designed to be inserted

inside of junction boxes. The module does not provide any protection against water and only essential protection for contact with solids

It is forbidden to install the module in areas not

adequately protected, near sources of heat and near metal surface

For your safety, do not work near the winding roller while the motor is powered

The product is not intended for use of persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they are supervised
or given instructions on how to use the product by a person responsible for their safety

Before operating on the roller shutter/awning, make sure there are no people or objects in the area

involved in its movement. Check the automation during the movement and keep people at a safe distance, until the movement ends

Do not allow children to play with the appliance or

with the fixed control devices. Furthermore, keep the portable control devices (remote controls) out of reach of children

Do not operate on the roller shutter/awning when maintenance

operations are being carried out (e.g. window cleaning). If the control device is automatic, disconnect the motor from the power line

01.2 Warnings for installation

01.3 Warnings for use

Power supply:

120 o 230 Vac, 50/60 Hz

Contact capacity:

7A @ 250 Vac

Dimension:

45 x 38 x 25 mm

Weight:

40 gr

Working temperature:

–20°C / +55°C

Working time:

120 s

Frequency:

433.42 Mhz

Memorizable radio code:

15 (rain sensor included)

Memorizable wind sensor:

4

Memorizable sun sensor:

1

Range (estimated):

100m outdoor, 20m indoor

Technical specifications

Make connections with power supply disconnected

Check that the power supply does not depend from electrical circuits for lighting

The supply line must be equipped with a circuit

breaker. The installer must fit an isolation device (with 3,5 mm minimum opening on the contacts) upstream of the system

The section of the connecting cables must be proportionate

to their length and to the absorption of the load, and in any case not less than 1,5 mm

You cannot connect more than one motor directly to the module. If it is necessary to connect more

than one motor to the module use the appropriate expansion cards

02. ELECTRICAL CONNECTIONS

The module can be powered at 120 Vac or 230 Vac. The supply voltage must be
applied to terminals (

) and (

)

1 phase

2 neutral .

02.1 Power supply

The motor windings must be connected to the terminals

and , the common wire

of the motor must be connected to terminal .

4

5

3 You can not connect more than

one motor directly to the module.

If it is necessary to connect more than one

motor to the module use the appropriate expansion cards.

02.2 Connecting the motor

03. FIRST INSTALLATION

01. Give power supply to the device. The motor performs one short movement.
02. Within 15 seconds:

If the movement is upward, press UP of transmitter.

If the movement is downward, press DOWN of transmitter.

03. The motor makes a brief upward movement.

1xUP

UP

1xDOWN

DOWN

or

MIR MAXI

radio receiver for mechanical motors

R

433,42 MHz

rev00.1_26/06/2017

04. MEMORIZATION/DELETION OF A RADIO DEVICE

01. Bring the motor in an intermediate position.
02. Press PROG of an already memorized transmitter for 5 s. The motor performs 2 upward movements.
03. Within 15 seconds, to memorize/delete:

a transmitter: press STOP of transmitter you want memorize/delete
a sensor: press «1» of sensor you want memorize/delete
a rain sensor: press «2» of rain sensor you want memorize/delete

04. 1 upward movement: device memorized!!

1 downward movement: device deleted!!
2 downward movement: error!!

PROG

(5 seconds)

NOTES: point 03. in battery powered sensors may be necessary to keep the button pressed up to 10 seconds.

point 04. is reported "error" if the radio code is not received in time, if the receiver's memory is full, if you try to delete the only memorized transmitter, if you try to

memorize more than 1 sun sensor or more than 4 wind sensor

P1

P2

P1

STOP

common

L N

L

N

C

M

MAX 7A

230V

~

120-230V

50-60Hz

1

2

3

4

5

M

I

R

MAXI

Summary of Contents for MIR MAXI

Page 1: ...si le cui capacità fisiche sensoriali o mentali siano ridotte oppure con mancanza di esperienza o di conoscenza a meno che esse non abbiano potuto beneficiare attraverso l intermediazione di una persona responsabile della loro sicurezza di una sorveglianza o di istruzioni riguardanti l uso del prodotto Prima di azionare l avvolgibile assicurarsi che persone o cose non si trovino nell area interess...

Page 2: ...i 05 Premi assieme PREV e NEXT per circa 2 secondi finché il motore segnala che il reset è stato effettuato 1 movimento su giù 06 Installa nuovamente il motore vedi sezione 3 di questo manuale 01 Porta il motore in posizione intermedia 02 Mantenendo premuto STOP premi anche PROG per circa 1 sec finché i LED si accendono 03 Premi 2 volte SU e 9 volte GIU 04 Premi STOP I led lampeggiano il motore ef...

Page 3: ...n instructions on how to use the product by a person responsible for their safety Before operating on the roller shutter awning make sure there are no people or objects in the area involved in its movement Check the automation during the movement and keep people at a safe distance until the movement ends Do not allow children to play with the appliance or with the fixed control devices Furthermore...

Page 4: ...ime PREV 7 times NEXT 17 appears on display 04 Press STOP The motor signals 1 up active 1 down inactive 05 To deactivate press DOWN To activate press UP 06 Press STOP The motor signals 1 up active 1 down inactive See the User manual of the transmitter at section RECEIVER MENU Function 17 Test radio ARCO FLUTE KUADRO KORT VISIO Other transmitters 01 Bring the motor in an intermediate position 02 Pr...

Reviews: