extended storage.
1.
Close fuel shut off valve.
2.
Siphon excess gasoline from tank.
3.
Start engine until it stops from lack of fuel. This will use up all the fuel
in the carburetor and prevent formation of deposits due to evaporation of
fuel.
4.
Remove spark plug and pour 2 oz. of SAE-30 or SAE-40 motor oil
into the cylinder. Slowly crank the engine 2 or 3 times to distribute the oil
throughout the cylinder. This will help prevent rust during storage. Replace
spark plug.
5.
Store the unit in an upright position in a cool, dry, well ventilated area.
TROUBLESHOOTING
WON'T START
Throttle fully open
Hand lever wire broken
No gas
Dirty gas
No oil
Gas filter plugged
Gas line plugged
Hole in gas line
Gas supply valve turned off
Dead-man safety switch is off
Safety switch wire or connectors not making good contact
Other engine problems (Refer to engine manual)
STARTS BUT NO HIGH SPEED
Engine problems
Throttle cable broken or seized