4.4

 

P

OWER SUPPLY

 

 

The module must be powered by 230 Vac. The power supply must be apply to the terminals L and N. Connect the grounding system to the specific terminal. 

 

4.5

 

C

ONNECTING OF THE MOTORS

 

 

The motors must be connected to terminals MOTOR1 and MOTOR2, following the numbering reported on the wires of the motors. The wires grounding of the motors must be 

connected to the specific terminal. 

 

4.6

 

C

ONNECTING OF THE COMMAND BUTTONS

 

 

The command buttons must to be connected to terminals M, C, M, the common wire of the buttons must be connected to terminal C. The command buttons must be with 
momentary positions (hold to run), do not use switches with maintained position. More command buttons can be connected to the unit through a parallel connection. To apply 
a command up or down, press the corresponding button for at least 0.5 seconds, to stop the manoeuvre briefly press any of the buttons. The command buttons are subjected 
to low voltage. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

5. FIRST INSTALLATION 

 

5.1

 

M

EMORIZATION OF THE FIRST TRANSMITTER

 

 

When you turn ON the module for the first time, the module commands 4 small movements to the motors: 

 

- If the 4 movements are upward, press the "UP" button of the transmitter you want to memorize 

 

- If the 4 movements are downward, press the "DOWN" button of the transmitter you want to memorize 

 

If after 8 seconds from the end of the 4 small movements the module has not yet received a valid UP or DOWN command, the module exits the programming and the motors 
will be operated only via the command buttons. 
 

5.2

 

R

EGULATION OF THE LIMIT SWITCHES

 

 

To regulate the limit switches of the system, you must to operate ONLY on MOTOR 2. On MOTOR 1 is not possible the regulation of the limit switches, it “follows” 

the setting of MOTOR 2. 

- To regulate the UPPER limit switch: press UP of the transmitter and operate on the white or blue screw (see the user manual of the motor) of MOTOR 2 until the system 

reaches the desired limit. 

- To regulate the LOWER limit switch: press DOWN of the transmitter and operate on the white or blue screw (see the user manual of the motor) of MOTOR 2 until the system 

reaches the desired limit. 

NOTE: the Operating Time is 130 s. If you need more time to finish the regulation, press again UP or DOWN. 
 
 
 
 
 

MAIN

POWER SUPPLY

+

+

+

MOTOR 1

MOTOR 2

4  3  2  1

1  2  3  4  5  6

BOA

RD 

FU

SE

M

O

TOR

 FU

S

E

FUSE
200 mA

FUSE 6A

M C M

L N

L
N

6
5
4
3
2
1

4
3
2
1

1 -> BROWN
2 -> BLACK
3 -> BLUE
4 -> GRAY

1 -> BROWN
2 -> BLACK
3 -> BLUE
4 -> GRAY
5 -> ORANGE
6 -> WHITE

MOTOR 1

-5 wires
-without regulation of the
 mechanical limit switches

MOTOR 2

-7 wires
-with regulation of the
 mechanical limit switches