WARNING:  To  avoid  an  overheating  of  the  combustion  chamber  the  fins  must  never  be  completely 
closed. For this reason a blocking bar prevents the complete closure of the fins. 
BF 

space heaters have been designed for use in medium to big sized rooms and buildings where a fixed heating 

system is needed.  
Heat is produced by combustion and the heat from smoke is transmitted to fresh air through the metal walls of the 
combustion  chamber  and  the  heat  exchanger.  The  combustion  chamber  is  of  the  type  where  smoke  follows  a 
course of two modules.  
Air and smoke pass through separated ducts, both of which are welded and sealed. When, after combustion, the 
waste gases have cooled, they get expelled through a duct that has to be connected to a chimney or chimney flue 
which must be big enough to guarantee that smoke gets efficiently expelled. 
Air used for combustion gets aspirated directly from the room or building that is being heated. It is therefore very 
important the room or building to be properly ventilated so that there is enough fresh air circulating at all times. 
Hot air can be sent in the desired direction by moving the fins on the air head.  

BF

  heaters  can  operate  with  ON-OFF  type  and  fuelled  by  heating  oil  burners.  Where  burners  use  oil,  a  front 

attached  fuel  tank  is  provided  (4).  There  are  two  safety  devices  which  are  activated  in  case  of  serious 
malfunctioning. The burner control device, which is mounted on the burner and  is provided with a restart button 
that  automatically  stops  the  burner  if  the  flame  turns  off,  while  the  manual  restarting  type  overheat  thermostat 
activates if the temperature of the combustion chamber reaches the set maximum limit. 
If  any  of  those  safety  devices  are  activated,  you  should  check  carefully  what  the  problem  is  before  pressing  the 
restart  button  and  restarting  the  heater  (check  the  “FUNCTIONING  PROBLEMS:  CAUSES  AND  SOLUTIONS” 
paragraph).    
 

GENERAL ADVICE 

WARNING:  Only  chosen  and  by  the  manufacturer  supplied  burners  can  be  used.  If  another  type  of 
burner is used, the heater no longer complies with the CE regulations. 

The  space  heater  has  to  be  installed,  set  up  and  used  in  accordance  with  existing  laws.  Here  are  a  few  general 
guidelines which should be followed: 

 

Follow the instructions of this manual very carefully. 

 

Don’t install the heater in places where there might be risk of explosion or fire. 

 

Flammable material should be kept at a safe distance from the heater (3 meters minimum). 

 

All fire prevention measures have to be enforced. 

 

The room or building to heat has to be sufficiently ventilated so that the heather disposes of the needed ait 

to work properly. 

 

The heater has to be near a chimney or a chimney flue and a suitable electric switchboard. 

 

Don’t let any children or animal get near the heater. 

 

After use, make sure that the disconnecting switch if off. 

 
When using any type of space heater, it is compulsory to: 

 

Not exceed the maximum furnace heat output level. 

 

Make  sure  that  a  proper  air  circulation  and  supply  is  provided  and  that  nothing  might  obstruct  the  air 

aspiration  and  expulsion:  that  can  be  caused,  for  example,  by  placing  covers  or  other  objects  on  the 
heater, or by  positioning it too close to walls or other large objects. If there is  an inadequate air supply, 
the combustion chamber might start overheating, getting the overheat thermostat to intervene.  

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for BF 105

Page 1: ...Hot air generator Operation and maintenance manual 4111 805 Edition 10 Rev 01 BF 35 BF 35 BF 35 BF 35 BF 45 BF 45 BF 45 BF 45 BF 75 BF 75 BF 75 BF 75 BF 95 BF 95 BF 95 BF 95 BF 105 BF 105 BF 105 BF 1...

Page 2: ...CONTROL BOARD 1 Commutator 2 Room thermostat 3 Burner 4 Fuel tank 5 Limit thermostat 6 Fan 7 Heat exchanger 8 Combustion chamber 9 Adjustable air head 5 3 2 1 4 6 7 8 9...

Page 3: ...e overheat thermostat activates if the temperature of the combustion chamber reaches the set maximum limit If any of those safety devices are activated you should check carefully what the problem is b...

Page 4: ...g and diffusing hot air An air head which can be connected to air ducts if the users chooses this option is supplied with every machine In this case and in particular if the diameter and length of the...

Page 5: ...ombustion chamber has completely cooled down VENTILATION When the commutator 1 gets turned to the position the heater will work in continuous fan mode MAINTENANCE WARNING The following operations have...

Page 6: ...hanger and the combustion chamber remove the burner the back lower panel C as well as the exchanger inspection panel E Using a vacuum cleaner or a ramroad remove soot and extraneous material Models BF...

Page 7: ...safety thermostat non restarted after repair 1 Check functioning and positioning of main switch 1 Check power wire 1 Check electric connections 1 Check fuses 2 Set main switch in the correct position...