PANELS, PLACE THEM ON THE
SIDES OF THE APPLIANCE (Fig. 2).
►3.1. HANDLING
Handle the cooler with the utmost care,
moving it horizontally.
►3.2. PRE-INSTALLATION AND
INSTALLATION METHOD
(Pic. 3)
During installation, the electrical
connection, water connection, use and
maintenance of the cooler, comply with
all local regulations and standards in
force.
►
3.2.1. The cooler must be installed
on a stable and level structure, so
as to prevent any risk (the structure
and the plugs must be adequate to
support the weight of the appliance).
►
3.2.2. Install the cooler in well
ventilated areas.
►
3.2.3. The cooler can only be installed
outside (on the roof or on the wall).
►
3.2.4. Install the cooler away from
fireplaces, heat sources and possible
sparks, in order to prevent serious
damage.
►3.3. DUCTING METHOD
By connecting a conduit to the cooler,
the outgoing air can be carried to where
cooling is required.
It is crucial for the entire ducting conduit
to be designed and structured correctly.
►
3.3.1. Use conduits of suitable
section (the average air speed inside
the conduit is 3-6 m/s).
►
3.3.2. The ducting should be as short
as possible.
►
3.3.3. Do not install the duct with
elbow bends.
►
3.3.4.
Do not branch the air flow into
several conduits.
NOTE: WE RECOMMEND USING
CONDUITS MADE OF GALVANISED
SHEET METAL, PLASTIC OR
FIBREGLASS.
►3.4. CONNECTION TO THE
ELECTRICITY MAINS
IMPORTANT: THE POWER SUPPLY
AND CONNECTION LINE MUST
BE INSTALLED BY A QUALIFIED
TECHNICIAN USING SUITABLE
DEVICES AND INSTRUMENTS, IN
ACCORDANCE WITH NATIONAL
REGULATIONS AND THE
STANDARDS IN FORCE.
►3.4.1. By removing the screws on the
side of the cooler you have access to
the interior of the appliance (Pic. 2).
►3.4.2. Pass the cables (power cable,
serial connection cable and any
temperature/humidity probe cable)
through the hole found near the
electrical panel (Fig. 4).
►3.4.3. Only connect and power the
cooler with the voltage and frequency
specified on the nameplate and with
cables of suitable section (observing
the phase-neutral polarity).
►3.4.4. Correct operation requires the
cooler to be earthed properly.
►3.4.5. Connect the control panel to
the serial (Fig. 5).
NOTE: WE RECOMMEND USING A 2P
10A RESIDUAL CURRENT DEVICE.