Page 21
6
Press the button to start the closing phase
The automation starts in
CLOSING
7
Press the button again to define the point from where you
want the door to slow down; otherwise, skip to the next
step. (DIP 5-ON)
The
automation
SLOWS
DOWN
8
Wait for the automation to stop automatically
The automation is in the
CLOSED position
9
Disconnect the power supply to the control unit.
Set DIP switch 9 to OFF
Learning phase complete
10 Power the control unit
9.2.
Partial opening learning phase
1
Cut off power to the control unit.
Set the DIP 9 switch to ON
Automation must be in the
CLOSED position.
2
Power the control unit
3
Press the N.O. button connected to terminals 16 and 17.
The automation should start
in the OPENING. Otherwise,
invert the wires of Terminal 3
and 4 and resume from point
1.
4
Press to define the opening partial position
The automation STOPS
5
Press the button to start the closing phase
Automation starts CLOSING
6
Wait for the automation to stop automatically
Automation is in the CLOSED
7
Cut off power to the control unit.
Set the DIP 9 switch to OFF
Learning phase completed
8
Power the control unit
The COMMISSIONING ends once the SELF-LEARNING phase of the WISLIDE 500KG
automation is complete.
If you notice a continuous ticking during operation, press the P1 PUSH BUTTON during
closing.
IF YOU DO NOT USE THE ENCODER: carry out the learning phase with the
speed trimmers already set correctly.