Master 1120.8 Instruction Manual Download Page 10

Page 10 

10.1.1.  Saving the radio remote control 

The  radio  remote  control  supplied  is  the  WI-CONTROL  model,  with  30  channels  and  a 
display,  which  transmits  at  the  radio  frequency  of  433.92  MHz;  no  other  radio  remote 
control model is provided for the

 

CLOUD

 

RADIO. Several actuators can be controlled with 

a single radio remote control, however each channel must correspond to a CLOUD RADIO 
actuator and thus a window. 

The encoding used varies for each channel, so each transmission will send a signal that is 
different  from  all  the  others.  It  follows  that  the  receiver  must  be  able  to  recognize  the 
enabled transmitters, thus the transmission codes should be saved following the procedure 
below: 

  Equip yourself with the radio remote control, checking beforehand that it is working, 

has charged batteries and is in good condition. 

  Select  the  desired  channel  on  the  radio  remote  control.  (Consult  the  instructions 

manual of the WI-CONTROL radio remote control)

  On  the  CLOUD  RADIO,  briefly  press  (for  about  1  second)  the  small  “

PRG

  button  

located near the terminal block. The slowly flashing LED indicates that it is waiting to 
receive a valid radio code. 

  Within 10 seconds, press any one of the up arrow 

STOP

 or down arrow 

 buttons 

two  times  (once  to  activate  the  display  of  the  radio  remote  control  and  the  second 
time to transmit the radio code)

  If  the  code  is  saved  correctly,  the  LED  will  emit  one  long  flash  (1  sec.)  to  confirm; 

then the LED will go out and remain at rest. 

  If the code is not saved correctly - due to the memory being full, for example, or the 

radio remote control being incompatible - the LED will emit a series of quick flashes 
for about 1 second; then the LED will go out and remain at rest. 

10.1.2.  Erasing the radio memory 

To  completely  erase  the  memory  of  the  radio  remote  control  on  the  machine,  press  the 

PRG

 button and hold it pressed for about 20 seconds until the LED begins to flash quickly. 

At this point you can release the button; the flashing continues until the memory has been 
completely erased. 

10.1.3.  Remotely saving a radio remote control 

A new radio remote control can be saved remotely – i.e., without accessing the 

PRG

 button 

–  only  if  at  least  one  radio  remote  control  has  already  been  saved  as  described  in  point 
10.1.1  and  you  have  the  radio  remote  control  which  is  already  recognized.  To  remotely 
save a radio remote control, follow the procedure below: 

  Equip  yourself  with  the  WI-CONTROL  radio  remote  control  to  be  saved  and  set  it  on 

the desired channel (see the instructions provided with the radio remote control)

  Equip  yourself  with  the  radio  remote  control  already  saved  and  operating  on  the 

CLOUD RADIO in question. 

  On  the  already  saved  radio  remote  control,  press  the  following  buttons  in  sequence: 

F1,  F2  and  then 

STOP

.  This  sequence  “opens”  the  memory  of  the  CLOUD  RADIO  (in 

the same way as pressing the PRG button)

Summary of Contents for 1120.8

Page 1: ...CHAIN OPERATED ACTUATOR ____ CLOUD RADIO FORCE 300 N MAXIMUM STROKE 400 MM ELECTRICAL FEEDING 230VAC 50 HZ INSTRUCTION MANUAL ENGLISH Art 1120 8 ...

Page 2: ...user manuals provided with the product indicate presumed in conformity with directives issued by the EU MASTER holds the technical file with all the documentation to show that our products have all been inspected to ensure compliance with directives conformity Symbols used in the manual DANGER This indication draw the attention about potential dangers for safety and health of peoples and animals I...

Page 3: ...te control 9 10 1 1 Saving the radio remote control 10 10 1 2 Erasing the radio memory 10 10 1 3 Remotely saving a radio remote control 10 10 2 Control with conventional button 11 10 3 Ventilation function 11 11 Rain detection sensor 11 12 Predominance of the commands 12 13 Programming actuator 12 13 1 Limit switches at opening 12 13 2 Limit switches at closure 12 14 Assembly 13 14 1 Preparation o...

Page 4: ...ndicated on the technical data label on the appliance This machine is destined exclusively for the use for which it has been designed and the manufacturer accepts no responsibility for damage incurred by improper use The actuator is destined exclusively for installation indoors For any special application we recommend you consult the manufacturer beforehand Power supply installation must comply wi...

Page 5: ...unction switch the appliance off at the general switch and call for the services of a qualified technician 2 Formulas and recommendations for installation 2 1 Calculation of opening closure force Using the formulas below approximate calculations can be made for the force required to open or close the window considering all the factors that determine the calculation Symbols used for the calculation...

Page 6: ...otor controlled by an electronic function device Window opening can be programmed to open at 100 200 300 and 400 mm see respective chapter During closure the end course uses a self regulating electronic process with power absorption and therefore requires no regulation The actuator leaves the factory with factory settings of 1 cm for the return course which allows the actuator to be assembled with...

Page 7: ...utopositioning Static hold force 1 700 N Connection of two or more devices in parallel YES Limit switch stop at opening Electronic Limit switch stop at closure At absorption of charge Dimensions 386 5x59x37 Weight 1 170 kg Weight as delivered 1 350 Kg Any information reported in this table is not binding and may be susceptible to variations without notice 6 Label data and markings The actuators ha...

Page 8: ...ectric power supply cables The cross section of the electric power supply conductors must comply with current standards on electrical systems without prejudice to standard EN 60335 for connected electrical devices 8 Electric power supply and sensor connection 8 1 Electric power supply cable The power supply cable is already wired to the actuator It is used for the electric power supply of the syst...

Page 9: ...the manual control with 3 conductors the common conductor on COM the conductor for opening on IN 1 and the conductor for closing on IN 2 10 Open and close commands 10 1 Remote electronic control Radio remote control The WI CONTROL radio remote control is the standard equipped device for controlling the CLOUD RADIO motor For more details on the characteristics and operation of the WI CONTROL radio ...

Page 10: ...the radio code If the code is saved correctly the LED will emit one long flash 1 sec to confirm then the LED will go out and remain at rest If the code is not saved correctly due to the memory being full for example or the radio remote control being incompatible the LED will emit a series of quick flashes for about 1 second then the LED will go out and remain at rest 10 1 2 Erasing the radio memor...

Page 11: ...ce F1 F2 up arrow The window opens and if no other commands are given closes again automatically after 5 minutes In the case in which the rain sensor a manual command or radio command intervened the ventilation function stops to restore the function the sequence of buttons must be pressed again 11 Rain detection sensor The rain sensor should be installed outside on the window frame and fixed with ...

Page 12: ...itch 1 in ON dip switch 2 in ON 13 2 Limit switches at closure The limit switch at closure is automatic electronically operated and cannot be programmed The actuator stops when the charge is absorbed when the window is completely closed and the weather stripping is completely depressed or when the charge absorbed is more than 15 of the nominal charge Attention The actuator at maximum charge exerci...

Page 13: ...of the window where the actuator is to be assembled is over 405 mm otherwise the actuator should not be installed Check that once the actuator has been installed the distance between the fixed part of the window frame where the actuator is to be assembled and the mobile part of the window frame where the bracket is to be fixed is greater than or equal to 0 mm Fig 1 If this is not the case the actu...

Page 14: ...t for outward opening windows onto the moveable part of the frame in accordance with the markings indicated on the template G Complete assembly of the chain terminal with the safety clip inserted onto the pin Ø4x32 provided in median position see fig 6 H Mount the actuator onto the brackets by inserting the two openings at each side onto the corresponding pins on the brackets I Rotate the actuator...

Page 15: ...screws provided Check that everything is aligned both horizontally and vertically F Mount the bracket for outward opening windows onto the moveable part of the frame in accordance with the markings indicated on the template G Complete assembly of the chain terminal with the safety clip inserted onto the provided pin Ø4x32 in median position see fig 11 H Mount the actuator onto the brackets by inse...

Page 16: ...oveable part of the frame in accordance with the markings indicated on the template F Complete assembly of the chain terminal with the safety clip inserted onto the provided pin Ø4x32 in median position see fig 15 G Mount the two brackets on to the sides of the actuator H Position the actuator onto the window frame and line up with the holes bored earlier Fix the actuator I Bring the chain termina...

Page 17: ...Page 17 14 5 Configurations ...

Page 18: ...ng for 2 seconds 2 per second The machine has not saved the radio remote control 6 Fast continuous flashing 2 per second Rain sensor active 7 Flashing for 5 seconds 2 per second Erasing the radio remote control memory 16 Checking for correct assembly Check that the window has closed completely even at the corners and check there are no obstacles caused by assembly in the wrong position Check that ...

Page 19: ...ator doesn t work No electricity supply for feeder Connecting cable not connected or wire not connected Winder on the transformer is broken Check state of safety switch Check all electrical connections of gear motor Replace the electronics card of the feeder LED is lit but actuator doesn t work Gear motor is damaged due to a shock Motor connection has unsoldered or has been disconnected Send actua...

Page 20: ...atter is valid as long as the purchaser possesses proof of purchase and completion of all agreed conditions of payment Guarantee of good function of appliances agreed by the manufacturer implies that the latter undertakes to repair or replace free of charge and in the shortest period possible any parts that break while under warranty The purchaser is not entitled to any reimbursement for eventual ...

Page 21: ...Page 21 21 Conformity ...

Page 22: ...age 22 MASTERITALY S r l s p 37 Conversano Castiglione km 0 7 z i 70014 Conversano Bari Italy C P 81 ITALY 39 080 4959823 Fax 39 080 4959030 http www masteritaly com info masteritaly com I460B 31 03 2016 ...