background image

Page 5 

 

Repairs should only be performed by qualified personnel at assistance centres 
authorised by the manufacturer.  

 

In  the  event  of  any  problems  or  queries,  consult  your  agent  or  contact  the 
manufacturer directly.  

 

Always  request  exclusive  use  of  original  spare  parts.  Failure  to  respect  this 
condition could compromise safety and invalidate the benefits contained in the 
warranty for the appliance. 

 

The  product  must  be  disposed  of  in  compliance  with  local  environmental 
regulations and not as household waste. 

2.  CONSTRUCTION AND REGULATORY REFERENCES 

 

This product was designed to be used with products suitably studied for the 
specific  application.  If  assembled  incorrectly,  use  of  the  product  with  other 
devices may result in damage or malfunctions. 

 

The  power  supply  system  and  electrical  connection  must  comply  with  EU 
standards for electrical systems. 

 

The  equipment  has  double  electrical  insulation  and  thus  does  not 
require  an  earth  wire.  All  devices  connected  to  the  station  must  be 
earthed by the installer unless equipped with double insulation. 

 

 

The  stations  are  constructed  according  to  European  Union  directives  and 
certified  in  conformity  with  the 

  mark.  All  the  devices  connected  to  the 

control  units  must  be  manufactured  according  to  current  regulations  and  in 
compliance with EC standards. 

3.  TECHNICAL DATA 

Model 

 

1120.30 
1120.31 

1120.32 
1120.33 

1120.34 

1120.35 

Power supply voltage of the 
station 

230 V~ (±10%) 50 Hz 

Output voltage 

 

24V = dc 

Maximum switchable output 
current per motor  

1 A      (2.5 A Fuse per module) 

Maximum power absorbed by 
the station 

 

75W 

100W 

150W 

Service type 

S1 

Double electrical insulation 

NO 

Setup for connection to 
external devices 

Wind sensor - Rain sensor - Daily timer 

- General open-close command 

Operating temperature 

-5 ÷ +60 ºC 

Degree of protection 

IP43 

The data provided in these illustrations is non-binding and subject to change, even without advance notice. 

Summary of Contents for 1120.30

Page 1: ...Codice 4420078 Edition 1407 CONTROL BOARD 1120 30 1120 31 1120 32 1120 33 1120 34 1120 35 UNIT FOR VENTILATION WITH SEVERAL 24V DC MOTORS MANUAL FOR INSTALLATION AND USE English...

Page 2: ...ing and indications for use provided with the product indicate presumed conformity to the directives issued by the European Community The manufacturer holds the technical archive with documentation pr...

Page 3: ...rs P005 P104 P204 P304 P404 P504 P604 13 6 3 3 Wind sensor Parameters P103 P203 P303 P403 P503 P603 13 6 3 4 Cron Timer input on main board Parameters P105 P205 P305 P405 P505 P605 13 6 3 5 Sensor pri...

Page 4: ...control have been designed and constructed exclusively to execute maneuvers for closing and or opening windows roll up blinds curtains and sunshades assisted by the aid of sensors for rain wind brigh...

Page 5: ...cal systems The equipment has double electrical insulation and thus does not require an earth wire All devices connected to the station must be earthed by the installer unless equipped with double ins...

Page 6: ...or adjustment operation The electrical power supply system must be designed and implemented in compliance with current standards Caution Check that the electric power supply used corresponds to that s...

Page 7: ...TING INFORMATION 6 1 General instructions The control unit is composed of a main board which is set up for insertion of expansion module boards The expansion module boards differ depending on the cont...

Page 8: ...ugh the programming menu or increase the value of the parameter within the menu The minus key is used to scroll down through the programming menu or decrease the value of the parameter within the menu...

Page 9: ...0 P103 Motor 1 Wind sensor function 0 2 F 0 Set the action when active as follows 0 none 1 open 2 close P104 Motor 1 Rain sensor function 1 2 F 2 Set the action when the input is active as follows 1 o...

Page 10: ...0 P303 Motor 3 Wind sensor function 0 2 F 0 Set the action when active as follows 0 none 1 open 2 close P304 Motor 3 Rain sensor function 1 2 F 2 Set the action when the input is active as follows 1 o...

Page 11: ...0 P503 Motor 5 Wind sensor function 0 2 F 0 Set the action when active as follows 0 none 1 open 2 close P504 Motor 5 Rain sensor function 1 2 F 2 Set the action when the input is active as follows 1 o...

Page 12: ...the display in case of error FULL radio remote control memory full Err the radio remote control is not recognized in either delete or write 6 3 Settable functions 6 3 1 General Open Close on main boar...

Page 13: ...e free n o contact The opening closing action of the window can be set using the P104 P204 P304 P404 P504 P604 menu Supply voltage 12V for rain sensor Tension V Maximum Current mA 12V DC 100mA Please...

Page 14: ...0 when a sensor intervenes the window goes to the position instructed by the sensor and remains there 6 3 7 Other parameters Parameters P101 P201 P301 P401 P501 P601 Add dEL rESE The parameter P101 P...

Page 15: ...The radio remote control is now saved and the motors are controlled by the respective channels CH1 motor 1 CH2 motor 2 CH6 motor 6 End Repeat the procedure for any other radio remote controls Advance...

Page 16: ...control to be saved press one of the arrow STOP or arrow buttons twice Now the second radio remote control is operational 7 OVERALL DIMENSIONS The container box is made of impact resistant ABS enginee...

Page 17: ...Page 17 8 CONNECTION DIAGRAM OF THE STATION Fig 7 1 Main Board Fig 7 2 Expansion Modules...

Page 18: ...4 station with the addition of a 230V ac module does not require any modifications of the power supply unit The 230V ac are powered directly from the mains network in this case it s not necessary to c...

Page 19: ...tter is valid as long as the purchaser possesses proof of purchase and completion of all agreed conditions of payment Guarantee of good function of appliances agreed by the manufacturer implies that t...

Reviews: