background image

Page 16 

 

Obtain  the  instructions  manual  of  the  PIK  radio  remote  control  for 
consultation. 

The programming is achieved by carrying out the following procedure: 

  Equip yourself with the PIK radio remote control to be saved and set it on any channel 

(see the instructions of the radio remote control)

  Equip yourself with the already saved and operational radio remote control, press the 

following buttons in sequence: 

F1

F2

 and then 

STOP

  Within 5 seconds on the radio remote control to be saved, press one of the 

 arrow, 

STOP

 or 

 arrow buttons twice.  

  Now the second radio remote control is operational. 

7.  OVERALL DIMENSIONS  

The  container  box  is  made  of  impact-resistant  ABS  engineering  plastic,  RAL7035  grey 
colored, having a cover with gasket and IP43 degree of protection.  

The feed-through holes for the cables, both those for the electric power supply and those 
coming  from  the  sensors,  as  well  as  those  going  to  the  motors  to  be  controlled,  are  not 
present on the box. The holes must be made by the installer as needed.    

 

 

During  the  drilling  of  the  holes,  be  very  careful  so  as  not  to  damage  the 
electronic board. 

 

 

 

A

B

C

D

E

240

190

120

220

152

Dimension

 

Summary of Contents for 1120.30

Page 1: ...Codice 4420078 Edition 1407 CONTROL BOARD 1120 30 1120 31 1120 32 1120 33 1120 34 1120 35 UNIT FOR VENTILATION WITH SEVERAL 24V DC MOTORS MANUAL FOR INSTALLATION AND USE English...

Page 2: ...ing and indications for use provided with the product indicate presumed conformity to the directives issued by the European Community The manufacturer holds the technical archive with documentation pr...

Page 3: ...rs P005 P104 P204 P304 P404 P504 P604 13 6 3 3 Wind sensor Parameters P103 P203 P303 P403 P503 P603 13 6 3 4 Cron Timer input on main board Parameters P105 P205 P305 P405 P505 P605 13 6 3 5 Sensor pri...

Page 4: ...control have been designed and constructed exclusively to execute maneuvers for closing and or opening windows roll up blinds curtains and sunshades assisted by the aid of sensors for rain wind brigh...

Page 5: ...cal systems The equipment has double electrical insulation and thus does not require an earth wire All devices connected to the station must be earthed by the installer unless equipped with double ins...

Page 6: ...or adjustment operation The electrical power supply system must be designed and implemented in compliance with current standards Caution Check that the electric power supply used corresponds to that s...

Page 7: ...TING INFORMATION 6 1 General instructions The control unit is composed of a main board which is set up for insertion of expansion module boards The expansion module boards differ depending on the cont...

Page 8: ...ugh the programming menu or increase the value of the parameter within the menu The minus key is used to scroll down through the programming menu or decrease the value of the parameter within the menu...

Page 9: ...0 P103 Motor 1 Wind sensor function 0 2 F 0 Set the action when active as follows 0 none 1 open 2 close P104 Motor 1 Rain sensor function 1 2 F 2 Set the action when the input is active as follows 1 o...

Page 10: ...0 P303 Motor 3 Wind sensor function 0 2 F 0 Set the action when active as follows 0 none 1 open 2 close P304 Motor 3 Rain sensor function 1 2 F 2 Set the action when the input is active as follows 1 o...

Page 11: ...0 P503 Motor 5 Wind sensor function 0 2 F 0 Set the action when active as follows 0 none 1 open 2 close P504 Motor 5 Rain sensor function 1 2 F 2 Set the action when the input is active as follows 1 o...

Page 12: ...the display in case of error FULL radio remote control memory full Err the radio remote control is not recognized in either delete or write 6 3 Settable functions 6 3 1 General Open Close on main boar...

Page 13: ...e free n o contact The opening closing action of the window can be set using the P104 P204 P304 P404 P504 P604 menu Supply voltage 12V for rain sensor Tension V Maximum Current mA 12V DC 100mA Please...

Page 14: ...0 when a sensor intervenes the window goes to the position instructed by the sensor and remains there 6 3 7 Other parameters Parameters P101 P201 P301 P401 P501 P601 Add dEL rESE The parameter P101 P...

Page 15: ...The radio remote control is now saved and the motors are controlled by the respective channels CH1 motor 1 CH2 motor 2 CH6 motor 6 End Repeat the procedure for any other radio remote controls Advance...

Page 16: ...control to be saved press one of the arrow STOP or arrow buttons twice Now the second radio remote control is operational 7 OVERALL DIMENSIONS The container box is made of impact resistant ABS enginee...

Page 17: ...Page 17 8 CONNECTION DIAGRAM OF THE STATION Fig 7 1 Main Board Fig 7 2 Expansion Modules...

Page 18: ...4 station with the addition of a 230V ac module does not require any modifications of the power supply unit The 230V ac are powered directly from the mains network in this case it s not necessary to c...

Page 19: ...tter is valid as long as the purchaser possesses proof of purchase and completion of all agreed conditions of payment Guarantee of good function of appliances agreed by the manufacturer implies that t...

Reviews: