8
to cycle C1 (BACKWASH). The controller will indicate the total
regeneration time remaining. Filling tank in this position allows air
to escape from drain.
Open the bypass inlet valve ¼ turn and allow water to flow into the
mineral tank at a slow rate.
Warning: IF WATER ENTERS THE TANK TOO FAST, ALL THE
MEDIA WILL BE FLUSHED TO DRAIN DURING START UP.
2. When water is running steadily at the drain, open the bypass
valve’s inlet and outlet to their maximum position.
Simultaneously press the SET and UP buttons on the controller for 1
second then release, the motor will advance the cam to C2. Once C2
is displayed simultaneously press the SET and UP buttons on the
controller for 1 second then release, the motor will advance the cam
to C3. Repeat this procedure until the timer enters the C7 (FAST
RINSE) position. The filter will go through the rinsing cycle and then
automatically advance to (REGENERATION COMPLETE) C0 and
Time of Day will be displayed. This is treated water.
Logix Control Valve Timer Settings:
Note:
The control valve is preset at the factory. You only need to
set the time of day and number of days to regenerate, which is
preset at 1 am.