6
Electrical Requirements:
Always follow all local electrical codes when installing our water
treatment equipment.
1. Provide an 115v/60Hz properly grounded dedicated electrical
Outlet. (I
t’s very important that the polarity be correct)
Avoid using outlets that are switch controlled.
2. Maximum amperage required is 5 amps.
3. Make sure the electrical service provides power 24 hours per day.
We recommend installing a
surge protector
to protect unit from
power surges, which are not covered by warranty.
Filling Filter with Water:
1. Connect the MCA control valve transformer into the electrical outlet
provided.
2. Press and hold the Up and Down arrows simultaneously for three
seconds until the drive motor starts. When the drive motor stops, the
display will read
“C1” backwash position.
3. Open the inlet ball valve a ¼ turn of its full open position to allow
water to enter the water filter mineral tank slowly. The water is going
to enter the tank from the bottom of the distributor pipe and leave the
tank from the top. This will slowly purge all the air from the tank.
IF WATER ENTERS THE TANK TOO FAST, ALL THE RESIN WILL
BE FLUSHED TO DRAIN DURING START UP.
4. When only water is running to the drain, open the inlet and outlet ball
valves fully.
5. Once the drive motor stops, press the Up button to advance the
control valve to the fa
st rinse position. The display will read “C4”.
The fast rinse position will rinse the filter tank.
NOTE: THE TIMER WILL AUTOMATICALLY ADVANCE TO THE
SERVICE POSITION AND THE DISPLAY WILL READ TIME OF DAY.